RELEASED
PM7350 S/UNI-DUPLEX
DATA SHEET
PMC-1980581
ISSUE 5
DUAL SERIAL LINK PHY MULTIPLEXER
3. 3.3
Analog power supplies (QAVD, CAVD, RAVD, TAVD) must be
applied after VDD have been applied or they must be current limited to the
maximum latch-up current specification (100 mA). In operation, the
differential voltage measured between AVD supplies and VDD must be
less than 0.5 V. The relative power sequencing of the multiple AVD power
supplies is not important.
4. 3.4
Power down the device in the reverse sequence.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
44