CBUSY:
The indirect access status bit (CBUSY) reports the progress of an indirect
access. CBUSY is set to logic 1 when a write to the Receive Serial Indirect
Channel Select register triggers an indirect access and will remain logic 1 until
the access is complete. This register should be polled to determine when
data from an indirect read operation is available in the Receive Serial Indirect
Channel Data registers or to determine when a new indirect write operation
may commence. The CBUSY is not expected to remain at logic 1 for more
than two REFCLK cycles.