欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM7348 参数 Datasheet PDF下载

PM7348图片预览
型号: PM7348
PDF下载: 下载PDF文件 查看货源
内容描述: [ATM/SONET/SDH IC, CMOS, PBGA324,]
分类和应用: ATM异步传输模式
文件页数/大小: 318 页 / 1736 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM7348的Datasheet PDF文件第162页浏览型号PM7348的Datasheet PDF文件第163页浏览型号PM7348的Datasheet PDF文件第164页浏览型号PM7348的Datasheet PDF文件第165页浏览型号PM7348的Datasheet PDF文件第167页浏览型号PM7348的Datasheet PDF文件第168页浏览型号PM7348的Datasheet PDF文件第169页浏览型号PM7348的Datasheet PDF文件第170页  
S/UNI-IMA-4 Telecom Standard Product Data Sheet  
Released  
WORD  
BIT  
DATA FIELD  
DESCRIPTION  
22:20  
RESERVED  
19:16  
GROUP_TIMER2  
Group-level timer 2. Implemented as 4-bit down  
counter. The counter is loaded with the  
appropriate timeout value when the timer is  
enabled, and decrements on every timer tick,  
until it reaches zero. A timeout event is declared  
when a timer tick occurs and the counter equals  
to zero, if the timer is enabled.  
15  
GROUP_INT_ACTIVE  
Indicates whether there is currently an interrupt  
active from the group (including all the links).  
This bit is set to ‘1’ by RIPP upon generating an  
interrupt and cleared upon PM issuing a  
read_event command. No new interrupt will be  
generated once this bit is set.  
This field will remain at its current value during  
a group-restart.  
14  
GROUP_INHIBIT_STATU Group inhibiting status.  
S
‘0’: Group is not inhibited.  
‘1’: Group is inhibited.  
This field can be programmed by PM during  
group record initialization, and can be modified  
later using Inhibit_group Not_inhibit_group  
commands. Note it is possible to inhibit the  
group before actually issuing the add_group  
command.  
This field will remain at its current value during  
a group-restart.  
13  
12  
RESERVED  
FE_TRL_STATUS  
When set, indicates that the TRL specified in  
the last received ICP cell is a link that is “in-  
group”. If the TRL received in the last ICP cell is  
not “in-group”, this bit is cleared, and the TRL  
remains with the last specified valid TRL.  
During the period in which the specified TRL is  
not “in-group”, the scheduling of the cells played  
out to the ATM layer is not accurate and the  
depth of the DCB buffers may drift and cause  
DCB buffer overruns or underruns. If on group  
startup, the TRL is not detected to be “in-  
group”, the group will not start up.  
11  
GROUP_TIMING_ERRO  
R
Group timing error. The FE IMA transmit clock  
mode does not match the NE transmit clock  
mode.  
10  
9
RESERVED  
PM_ADJUST_DELY_INT  
PM adjust_delay procedure done interrupt. The  
adjust_delay procedure invoked by the PM  
command has successfully finished or aborted.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its customers’ internal use.  
Document No.: PMC-2020889, Issue 2  
166  
 复制成功!