S/UNI-IMA-4 Telecom Standard Product Data Sheet  
Released  
RIPP RX Link Configuration Record Memory  
Purpose: Contains the PM programmed configuration data for the corresponding RX links.  
Usage: IMA Groups only.  
Maintained by: PM.  
Record Size: 1 32-bit word.  
MEM_ADDR = Area_base_address + physical link number * 0x1+ Word Offset  
Table 11 RIPP RX Link Configuration Record Structure  
WORD  
BIT  
DATA FIELD  
DESCRIPTION  
0
31:18  
17:16  
RESERVED  
RX_LINK_GROUP_TAG  
Group tag value of the group to which this RX  
physical link has been assigned.  
This field is programmed by PM during link  
record initialization.  
15:11  
10  
RESERVED  
RX_ACTIVE_INT_EN  
RX Active Interrupt enable. When disabled,  
this event on this link cannot cause an entry  
to be written to the RIPP Interrupt FIFO for  
this group (although the status returned by  
read_event may be set).  
‘0’ Interrupt not enabled  
‘1’ Interrupt enabled.  
9
8
7
IDLE_CELL_INT_EN  
Idle cell interrupt enable. When disabled, this  
event on this link cannot cause an entry to be  
written to the RIPP Interrupt FIFO for this  
group (although the status returned by  
read_event may be set).  
‘0’ Interrupt not enabled  
‘1’ Interrupt enabled.  
FE TX UNUSABLE Interrupt enable. When  
disabled, this event on this link cannot cause  
an entry to be written to the RIPP Interrupt  
FIFO for this group (although the status  
returned by read_event may be set).  
‘0’ Interrupt not enabled  
‘1’ Interrupt enabled.  
FE_TX_UNUSABLE_INT_  
EN  
DIFF_DELAY_INT_EN  
Differential Delay Interrupt enable. When  
disabled, this event on this link cannot cause  
an entry to be written to the RIPP Interrupt  
FIFO for this group (although the status  
returned by read_event may be set).  
‘0’ Interrupt not enabled  
‘1’ Interrupt enabled.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its customers’ internal use.  
Document No.: PMC-2020889, Issue 2  
162  