S/UNI-IMA-4 Telecom Standard Product Data Sheet  
Released  
WORD  
BIT  
DATA FIELD  
DESCRIPTION  
6
LODS_OVERRUN_INT_E  
LODS, DCB overrun Interrupt enable. When  
disabled, this event on this link cannot cause  
an entry to be written to the RIPP Interrupt  
FIFO for this group (although the status  
returned by read_event may be set).  
N
‘0’ Interrupt not enabled  
‘1’ Interrupt enabled.  
5
4
3
2
1
0
LODS_UNDERRUN_INT_  
EN  
LODS, DCB underrun Interrupt enable.  
When disabled, this event on this link cannot  
cause an entry to be written to the RIPP  
Interrupt FIFO for this group (although the  
status returned by read_event may be set).  
‘0’ Interrupt not enabled  
‘1’ Interrupt enabled.  
LCD Interrupt enable. When disabled, this  
event on this link cannot cause an entry to be  
written to the RIPP Interrupt FIFO for this  
group (although the status returned by  
read_event may be set).  
‘0’ Interrupt not enabled  
‘1’ Interrupt enabled.  
LIF Interrupt enable. When disabled, this  
event on this link cannot cause an entry to be  
written to the RIPP Interrupt FIFO for this  
group (although the status returned by  
read_event may be set).  
‘0’ Interrupt not enabled  
‘1’ Interrupt enabled.  
Invalid_ICP interrupt enable. When disabled,  
this event on this link cannot cause an entry  
to be written to the RIPP Interrupt FIFO for  
this group (although the status returned by  
read_event may be set).  
‘0’ Interrupt not enabled  
‘1’ Interrupt enabled.  
LCD_INT_EN  
LIF_INT_EN  
INVALID_ICP_INT_EN  
RX_TIMEOUT_INT  
RESERVED  
Rx Timeout Interrupt enable. When disabled,  
this event on this link cannot cause an entry  
to be written to the RIPP Interrupt FIFO for  
this group (although the status returned by  
read_event may be set).  
‘0’ Interrupt not enabled  
‘1’ Interrupt enabled.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its customers’ internal use.  