欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM7347-BI 参数 Datasheet PDF下载

PM7347-BI图片预览
型号: PM7347-BI
PDF下载: 下载PDF文件 查看货源
内容描述: SATURN用户网络接口的J2 / E3 / T3 [SATURN USER NETWORK INTERFACE for J2/E3/T3]
分类和应用: 网络接口
文件页数/大小: 341 页 / 1733 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM7347-BI的Datasheet PDF文件第89页浏览型号PM7347-BI的Datasheet PDF文件第90页浏览型号PM7347-BI的Datasheet PDF文件第91页浏览型号PM7347-BI的Datasheet PDF文件第92页浏览型号PM7347-BI的Datasheet PDF文件第94页浏览型号PM7347-BI的Datasheet PDF文件第95页浏览型号PM7347-BI的Datasheet PDF文件第96页浏览型号PM7347-BI的Datasheet PDF文件第97页  
S/UNI®-JET Data Sheet  
Released  
RBLEN  
The RBLEN bit enables: the receive RED alarm (persistent OOF) indication to automatically  
generate a FERF indication in the DS3 transmit stream, or a BIP8 error detection in the E3  
G.832 Framer to generate a FEBE indication in the E3 G.832 transmit stream, or an LOF to  
generate a RLOF indication (A-bit) in the J2 transmit stream. When the E3 G.751 framer is  
selected, this bit has no effect.  
When RBLEN is logic one, TFRM[1:0] is 00 binary, and RFRM[1:0] is 00 binary, assertion  
of the RED indication by the framer causes a FERF to be transmitted by DS3_TRAN for the  
duration of the RED assertion. Also, for DS3 frame format, the OOFEN bit is internally  
forced to logic zero when RBLEN is logic one. When RBLEN is logic zero, assertion of the  
RED indication does not cause transmission of a FERF.  
When RBLEN is logic one, TFRM[1:0] is 01 binary, and RFRM[1:0] is 01 binary, any BIP8  
error indication by the E3 G.832 framer causes a FEBE to be generated by the E3 G.832  
TRAN. When RBLEN is logic zero, BIP8 errors detected by the E3 framer do not cause  
FEBEs to be generated by the E3_TRAN.  
When RBLEN is logic one, TFRM[1:0] is 10 binary, and RFRM[1:0] is 10 binary, any LOF  
error indication by the J2 framer causes the RLOF bit (also known as the A bit) to be set in  
the J2 transmit stream. When RBLEN is logic zero, LOF errors detected by the J2 framer do  
not cause the RLOF bit to be set in the transmit stream.  
AISEN  
The AISEN bit enables the RAI signal to automatically generate a FERF indication (RAI in  
G.751 or J2 mode) in the transmit stream. This bit operates regardless of framer selected  
(DS3, E3, or J2). When AISEN is logic one, assertion of the AIS indication (physical AIS for  
J2) by the framer causes a FERF/RAI to be transmitted by TRAN for the duration of the AIS  
assertion. When AISEN is logic zero, assertion of the AIS indication does not cause  
transmission of a FERF/RAI.  
Note: For the RAI to be automatically transmitted when in J2 format, the FEAC[5:0] bits in  
the XBOC Code Register must all be set to logic one. If the XBOC FEAC code is to be  
transmitted in J2 mode, LOSEN, OOFEN, AISEN, and LCDEN should all be set to logic  
zero.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990267, Issue 3  
93  