S/UNI®-JET Data Sheet
Released
16 D.C. Characteristics
T
= -40°C to +85°C, V
= 3.3V ±10%, V
< BIAS < 5.5 V
DD
A
DD
(Typical Conditions: T = 25°C, V
A
= 3.3 V, V
= 5 V)
BIAS
DD
Table 47 DC Characteristics
Symbol
Parameter
Min Typ Max
Units
Conditions
V
Power Supply
2.97
3.3
3.63
Volts
DD
BIAS
5 V Tolerant Bias
Current into 5 V Bias
VDD 5.0
6.0
5.5
Volts
µA
I
V
BIAS
= 5.5 V
BIAS
V
V
V
Input Low Voltage
0
0.8
Volts
Volts
Volts
Guaranteed Input Low voltage.
Guaranteed Input High voltage.
Guaranteed output Low voltage at
IL
Input High Voltage
2.0
BIAS
0.4
IH
OL
Output or Bi-directional
Low Voltage
0.23
2.93
VDD=2.97 V and I =maximum
OL
rated for pad. 4, 5, 6
V
Output or Bi-directional 2.4
High Voltage
Volts
Volts
Guaranteed output High voltage at
OH
T-
VDD=2.97 V and I
=maximum
OH
rated current for pad. 4, 5, 6
V
Reset Input Low
Voltage
0.8
Applies to RSTB, TRSTB,
TICLK[4:1], RCLK[4:1], TFCLK,
RFCLK, TCK, TDI, TMS, and
REF8KI.
V
V
I
Reset Input High
Voltage
2.0
Volts
Volts
Applies to RSTB, TRSTB,
TICLK[4:1], RCLK[4:1], TFCLK,
RFCLK, TCK, TDI, TMS, and
REF8KI.
Applies to RSTB, TRSTB,
TICLK[4:1], RCLK[4:1], TFCLK,
RFCLK, TCK, TDI, TMS, and
REF8KI.
T+
Reset Input Hysteresis
Voltage
0.5
TH
V
IL
V
IH
V
IL
V
IH
= GND. 1, 3
Input Low Current
Input High Current
Input Low Current
Input High Current
Input Capacitance
Output Capacitance
-100 -60
-10
µA
µA
µA
µA
pF
pF
pF
ILPU
IHPU
IL
1. 3
I
I
I
-10
-10
-10
0
0
0
6
6
6
+10
+10
+10
= V
.
DD
= GND. 2, 3
2, 3
= V
DD
.
IH
C
C
C
t =25°C, f = 1 MHz
A
t =25°C, f = 1 MHz
A
t =25°C, f = 1 MHz
A
IN
OUT
IO
Bi-directional
Capacitance
IDDOP1
Operating Current
165
mA
VDD = 3.63 V, Outputs Unloaded
(DS3/PLCP mode)
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-1990267, Issue 3
320