欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM7347-BI 参数 Datasheet PDF下载

PM7347-BI图片预览
型号: PM7347-BI
PDF下载: 下载PDF文件 查看货源
内容描述: SATURN用户网络接口的J2 / E3 / T3 [SATURN USER NETWORK INTERFACE for J2/E3/T3]
分类和应用: 网络接口
文件页数/大小: 341 页 / 1733 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM7347-BI的Datasheet PDF文件第266页浏览型号PM7347-BI的Datasheet PDF文件第267页浏览型号PM7347-BI的Datasheet PDF文件第268页浏览型号PM7347-BI的Datasheet PDF文件第269页浏览型号PM7347-BI的Datasheet PDF文件第271页浏览型号PM7347-BI的Datasheet PDF文件第272页浏览型号PM7347-BI的Datasheet PDF文件第273页浏览型号PM7347-BI的Datasheet PDF文件第274页  
S/UNI®-JET Data Sheet  
Released  
Control Bit  
Transmit Operation  
Receive Operation  
Extracts the Tributary Justification Bits on the  
ROH output pin when the Jk bits are  
configured as overhead.  
Jk: Tributary  
When the device is  
Justification Bits  
configured as a E3 G.751  
framer, the Tributary  
Justification Bits can be  
inserted on the TDATI input  
pin the same way as normal  
payload data.  
When the device is  
configured for ATM  
application, the Tributary  
Justification Bits are used a  
payload bits.  
13.6 G.832 E3 Frame Format  
The S/UNI-JET provides support for the G.832 E3 frame format. This format can be extended to  
allow for direct byte mapping of ATM cells. The G.832 E3 frame format is shown in Figure 14.  
Figure 14 G.832 E3 Frame Structure  
59 columns  
FA1  
EM  
TR  
FA2  
MA  
NR  
GC  
530 octet payload  
The processing of the overhead bits in the G.832 E3 frame is described in Table 40. In the  
transmit direction, the overhead bits can be inserted on a bit-by-bit basis from a user supplied data  
stream using the TOH, TOHINS, TOHFP, and TOHCLK signals. In the receive direction, the  
overhead bits are brought out serially on the ROH data stream.  
Table 40 G.832 E3 Frame Overhead Operation  
Control  
FA1, FA2:  
Frame Alignment Pattern  
Transmit Operation  
Receive Operation  
Inserts the G.832 E3 frame  
Searches the receive stream for the G.832 E3  
frame alignment pattern. When the pattern is  
detected for two consecutive frames, an in-  
frame condition is declared. Note: There is no  
alignment pattern (F628H).  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990267, Issue 3  
270