S/UNI®-JET Data Sheet
Released
REDI
The REDI bit indicates that a change of state of the DS3 RED indication has occurred. The
DS3 RED indication is visible in the REDV bit location of the DS3 FRMR Status Register.
When the REDI bit is a logic one, a change in the RED state has occurred. When the REDI
bit is logic zero, no change in the RED state has occurred.
COFAI
The COFAI bit is set to logic one when a change of frame alignment is detected. A COFA is
generated when a new DS3 frame alignment is determined that differs from the last known
frame alignment. The COFAI bit position is set to logic zero when this register is read.
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-1990267, Issue 3
134