S/UNI®-JET Data Sheet  
Released  
Register 331H: DS3 FRMR Additional Configuration Register  
(ACE=1 in Register 333H)  
Bit  
Type  
Function  
Unused  
Unused  
AISONES  
BPVO  
EXZSO  
EXZDET  
SALGO  
DALGO  
Default  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
X
X
0
0
0
0
0
0
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
DALGO  
The DALGO bit determines the criteria used to decode a valid B3ZS signature. When  
DALGO is set to logic one, a valid B3ZS signature is declared and three zeros substituted  
whenever a zero followed by a bipolar violation of the opposite polarity to the last observed  
BPV is seen. When the DALGO bit is set to logic zero, a valid B3ZS signature is declared  
and the three zeros are substituted whenever a zero followed by a bipolar violation is  
observed.  
SALGO  
The SALGO bit determines the criteria used to establish a valid B3ZS signature used to map  
BPVs to LCV indications. Any BPV that is not part of a valid B3ZS signature is indicated as  
an LCV. When the SALGO bit is set to logic one, a valid B3ZS signature is declared  
whenever a zero followed by a bipolar violation is observed. When SALGO is set to logic  
zero, a valid B3ZS signature is declared whenever a zero followed by a bipolar violation of  
the opposite polarity to the last observed BPV is seen.  
EXZDET  
The EXZDET bit determines the type of zero occurrences to be included in the LCV  
indication. When EXZDET is set to logic one, the occurrence of an excessive zero generates  
a single pulse indication that is used to indicate an LCV. When EXZDET is set to logic zero,  
every occurrence of three consecutive zeros generates a pulse indication that is used to  
indicate an LCV. For example, if a sequence of 15 consecutive zeros were received, with  
EXZDET=1 only a single LCV would be indicated for this string of excessive zeros; with  
EXZDET=0, five LCVs would be indicated for this string (i.e. one LCV for every three  
consecutive zeros). Refer to Table 14.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990267, Issue 3  
130