PM7344 S/UNI-MPH  
DATA SHEET  
PMC-950449  
ISSUE 6  
MULTI-PHY USER NETWORK INTERFACE  
b) If FLG=0 (i.e. an abort has been received) and the link state was active,  
then set the link state to inactive, discard the current frame, and go to step 1.  
c) If FLG=1 and the link state was inactive, then set the link state to active,  
discard the last data byte, and go to step 1.  
ELSE  
d) Save the last data byte read.  
e) If EOM=1, then read the CRC and NVB[2:0] bits of the RFDL Status  
Register to process the frame properly.  
f) If FE=0, then go to step 2, else go to step 1.  
The link state is typically a local software variable. The link state is inactive if the  
RFDL is receiving all ones or receiving bit-oriented codes which contain a  
sequence of eight ones. The link state is active if the RFDL is receiving flags or  
data.  
Interrupt Mode  
In the interrupt driven mode, the processor controlling the RFDL uses either the  
RDLINT[x] output, or the main processor INTB output (RDLINTE bit of the  
Datalink Options Register is set to logic 1) and the Source Selection/Interrupt ID,  
Interrupt Source #1 and Interrupt Source #2 Registers, to determine when to  
read the RFDL Receive Data Register. The RXDMASIG bit in the Datalink  
Options Register should be set to logic 1. RDLINTE of the same register should  
be set to logic 1 if the INTB output is used as the interrupt source. The  
processor interrupt service routine should process the data in the following order:  
1. Wait for an interrupt originating from the RFDL. Once the interrupt is set,  
then proceed to step 2.  
2. Read the RFDL Receive Data Register.  
3. Read the RFDL Status Register to check for the following:  
a) If OVR=1, then discard the current frame and go to step 1.  
ELSE  
b) If FLG=0 (i.e. an abort has been received) and the link state was active,  
then set the link state to inactive, discard the current frame, and go to step 1.  