PM7340 S/UNI-IMA-8
PRELIMINARY
INVERSE MULTIPLEXING OVER ATM
DATA SHEET
PMC-2001723
ISSUE 3
INVERSE MULTIPLEXING OVER ATM
Symbol Parameter
Min
1.656
3.03
3.03
0
Typ
1.8
3.3
3.3
Max
1.944
3.56
3.56
0.8
Units Conditions
V
V
V
V
Power Supply
Power Supply
Power Supply
Volts
Volts
Volts
VDDI
VDDO
VDDQ
IL
Input Low Voltage
Volts Guaranteed Input
Low voltage.
V
V
Input High Voltage
2.0
Volts Guaranteed Input
High voltage.
IH
Output or Bi-
directional Low
Voltage
TBD
TBD
0.4
Volts Guaranteed output
OL
Low voltage at
VDD=3.03V and
I =maximum rated
OL
for pad.
V
Output or Bi-
directional High
Voltage
2.4
2.0
Volts Guaranteed output
OH
High voltage at
VDD=3.03V and
I
=maximum rated
OH
current for pad.
V
V
V
Reset Input High
Voltage
Volts Applies to RSTB and
T+
T-
TRSTB only.
Reset Input Low
0.8
Volts Applies to RSTB and
TRSTB only.
Voltage
Reset Input
Hysteresis
Voltage
TBD
Volts Applies to RSTB and
TH
TRSTB only.
10
-10
-10
-10
100
+10
+10
+10
I
I
I
I
Input Low Current
Input High Current
Input Low Current
Input High Current
Input Capacitance
µA
µA
µA
µA
V = GND. Notes 1
IL
ILPU
IHPU
IL
and 3.
0
0
0
V
= V . Notes 1
DD
IH
and 3.
V = GND. Notes 2
IL
and 3.
V
= V . Notes 2
DD
IH
IH
and 3.
t =25°C, f = 1 MHz
C
C
5
5
pF
pF
IN
A
Output
t =25°C, f = 1 MHz
A
OUT
Capacitance
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE