PM7340 S/UNI-IMA-8
PRELIMINARY
INVERSE MULTIPLEXING OVER ATM
DATA SHEET
PMC-2001723
ISSUE 3
INVERSE MULTIPLEXING OVER ATM
Register 0x366: DLL Control Status
Bit
Type
Function
Default
15:1
0
R
R
Reserved
RUN
X
0
The DLL Control Status Register provides information of the DLL operation.
RUN:
The DLL lock status register bit (RUN) indicates the DLL has locked. After
system reset, RUN is logic zero until the DLL has locked. For proper
operation the DLL must be indicate RUN.
The RUN register bit is cleared only by a system reset .
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
257