S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
Bit  
15  
Name  
Description  
CC_Activate_End_to_E Enables Continuity Checking on end-to-end flows. If the ForceCC register  
nd  
bit is logic 0, then when no user or end-to-end CC cells are transmitted  
over a 1.0 second (nominal) interval, an end-to-end CC OAM cell is  
generated. The end-to-end CC cell is generated at an interval of one per  
second (nominally). If the connection is an F4 OAM connection that is  
being aggregated, then any cells transmitted on any of the constituent F5  
connections are considered user cells.  
If the ForceCC register bit is logic 1, then when the  
CC_Activate_End_to_End bit is logic 1, an end-to-end CC cell will be  
generated at an interval of once per second (nominally), regardless of the  
flow of user cells. ITU-T I.610 9.2.1.1.2, 9.2.2.1.2.  
14  
FM_interrupt_enable  
This bit enables the generation of segment and end-to-end AIS, RDI  
Continuity Check, and OAM Failure alarm interrupts. If this bit is logic 1,  
the S/UNI-ATLAS-3200 will assert OAM Failure and segment and end-to-  
end AIS, RDI and Continuity Check interrupts, as required, regardless of  
whether or not the S/UNI-ATLAS-3200 is a connection end-point (segment  
or end-to-end) for the connection. This bit would typically be programmed  
to logic 1 at segment or end-to-end-points only. If this bit is logic 0, no  
alarm interrupts will be asserted, however, the Status field will reflect the  
connection state.  
13:6  
5
Generated OAM Defect  
Type [7:0]  
The Defect Type bits determine the Defect Type that is inserted into AIS  
cells generated due to the CC_AIS_RDI process, via per-PHY AIS, and via  
the Send_AIS_End_to_End or Send_AIS_Segment bits, and into RDI cells  
generated via the CC_AIS_RDI process, via per-PHY RDI generation, or  
via the per-VC bits Send_RDI_End_To_End or Send_RDI_Segment.  
The F4toF5OAM bit indicates whether or not an F5 (VCC) connection will  
send AIS or RDI cells due to an associated F4 (VPC) connection being in  
AIS alarm. This bit is only significant if the connection is an F5. When an  
F4 (VPC) is terminated (i.e. there is an F4 connection end-point which is  
associated with this F5 connection) at the S/UNI-ATLAS-3200, the F5  
connections are switched. If the F4 receives AIS cells, then the F5  
connections will send AIS and/or RDI cells once per second, carrying the  
Defect Location and Defect Type contained in the received F4 AIS cells. If  
F4toF5OAM is set to logic 0, then this process is disabled, and no F5 AIS  
or RDI cells will be generated based on the condition of the associated F4.  
F4toF5OAM  
4
AUTO_RDI  
The AUTO_RDI bit enables the generation of segment and end-to-end RDI  
cells while in an AIS alarm or Continuity alarm state. If AUTO_RDI is logic  
1, an RDI cell is transmitted (and looped from the Cell Processor to the  
reverse cell stream) immediately upon the reception of the first AIS cell at a  
flow end-point. (if the S/UNI-ATLAS-3200 is an end-to-end point for that  
connection, an end-to-end RDI cell will be generated, if the S/UNI-ATLAS-  
3200 is a segment end point, a segment RDI cell will be generated, and if  
the S/UNI-ATLAS-3200 is both a segment and end-to-end point, both types  
of RDI cells will be generated) and once per second thereafter until the AIS  
state is exited. Similarly, if the CC_AIS_RDI bit is logic 1, RDI cells are  
generated once per second if no user or CC cells have been received in  
the last 3.5 +/- 0.5 seconds. RDI cells can also be transmitted if the  
Send_RDI_segment and Send_RDI_end_to_end bits are set, or if the  
PHYRDI register bits are set.  
3
CC_AIS_RDI  
If this bit is a logic 1, AIS or RDI cells are generated at one second  
intervals upon the declaration of a CC_alarm (assuming AIS_alarm is not  
also declared).  
If the connection is not a segment or ETE end point, then ETE AIS will be  
generated once per second on declaration of ETE CC alarm. If  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990553, Issue 4  