S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet
Preliminary
11.5.2 Search
Register 0x10B: Search Engine Configuration
Bit
31 : 27
Type
Function
Unused
Default
X
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Search_From_IBCIF
LPHY[2]
LPHY[1]
LPHY[0]
LA[4]
LA[3]
LA[2]
LA[1]
LA[0]
STARTA[6]
STARTA[5]
STARTA[4]
STARTA[3]
STARTA[2]
STARTA[1]
STARTA[0]
LB[3]
LB[2]
LB[1]
LB[0]
STARTB[6]
STARTB[5]
STARTB[4]
STARTB[3]
STARTB[2]
STARTB[1]
STARTB[0]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Search_From_IBCIF
When this bit is a logic 1, cells from the Input Backwards Cell Interface are searched by the
search engine as if they were from the Input Cell Interface. When this bit is logic 0, the cells
are assumed to carry the 16-bit VC Record Address to which they belong in prepended bytes,
as shown in Table 38. In any event, the cells MUST carry the PHYID as shown in Table 38.
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-1990553, Issue 4
219