S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
Xlate_From_IBCIF  
When this bit is logic 1, then all cells from the Input Backwards Cell Interface are translated  
as if they came from the Input Cell Interface, i.e. as controlled by the XVPIVCI, XPREPO,  
XHEC, and XUDF, and Cell_Info_to_OCIF bits. This is the default choice. When this bit is  
logic 0, no header translation is performed on cells from IBCIF except as specified by  
IBCIF_P2_To_HECUDF and IBCIF_P2_To_P1.  
Reserved  
This function is not supported.  
Rtd_LB_to_UP_at_End  
When this bit is logic 1, then on connections with LB_Route = “01” or “10”, Returned  
Loopback cells are routed to the microprocessor at flow end points whether or not the Source  
ID of the Rtd LB cell matches the value programmed in the Loopback ID Registers. When  
this bit is logic 0, Returned Loopback cells are routed to the micro only if the source ID in the  
cell matches the value programmed in the Loopback ID Registers.  
APStoOCIF  
When APStoOCIF is logic 1, APS Coordination Protocol cells are not dropped at OAM flow  
end-points. When APStoOCIF is logic 0, APS cells are dropped at flow end-points like other  
OAM cells. APS cells may be copied to the Microprocessor Cell Interface or BCIF on a per-  
VC basis via the APStoUP bit in the VC Configuration field of the VC table, and the  
APStoBCIF bit in this register.  
APStoBCIF  
If the APStoBCIF bit is logic 1, then for those connections which the APStoUP bit is set to  
logic 1 in the VC Table Configuration field, the APS cells will be routed to the BCIF instead  
of to the microprocessor.  
LBtoOCIF  
When LBtoOCIF is logic 1, Loopback cells are not dropped at flow end-points or due to  
LB_Route functionalitybut will be passed to the OCIF. When LBtoOCIF is logic 0, all  
Loopback cells are dropped at flow end-points. Regardless of the setting of this bit, the  
routing of Loopback cells to MCIF and BCIF is controlled by the LB_Route[1:0] bits in the  
VC Table OAM Configuration field. This bit is intended to be used when an external device  