S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
COUNT1[7:0]  
The COUNT1[7:0] controls which cells the Cell Processor includes in its first per-connection  
32-bit cell count. The COUNT1[7:0] field is programmed as follows:  
Cell  
User Cells  
OAM Cells  
RM Cells  
Invalid PTI/VCI  
Type  
CLP Bit  
1
0
1
0
1
0
1
0
COUNT1  
COUNT1  
COUNT1  
COUNT1  
COUNT1  
COUNT1  
COUNT1  
COUNT1  
Register  
[7]  
[6]  
[5]  
[4]  
[3]  
[2]  
[1]  
[0]  
Bit  
A logic 1 written to any of the COUNT1[7:0] bits enables counting on that particular stream.  
For example, to enable counting of CLP=0+1 User and OAM cells only, the register  
configuration would be COUNT1[7:0] = 0xF0. If COUNT1[7:0] = 0x00, the first generic  
cell count for all connections is disabled. OAM and RM cells include those with invalid  
CRC-10s. Invalid PTI/VCI cells include F5 cells with PTI = “111”, F4 cells with VCI = 0, F4  
cells with VCI = 7 through 15, and (if vp_rm_pti6 is set to logic 1 in the Routing  
Configuration Register) F4 RM cells which have PTI not equal to “110”. Note that cells  
which cannot reliably be identified with a particular connection (those that suffer UTOPIA  
parity errors and failed searches) and cells that are generated by S/UNI-ATLAS-3200 are not  
counted at all.  
COUNT2[7:0]  
The COUNT2[7:0] register bits controls which cells the Cell Processor includes in its second  
per-connection 32-bit cell count. The COUNT2[7:0] field is programmed exactly the same as  
the COUNT1[7:0] field.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990553, Issue 4  