PM6341 E1XC  
DATA SHEET  
PMC-910419  
ISSUE 8  
E1 FRAMER/TRANSCEIVER  
Pin Name Type  
Pin No.  
PQFP PLCC  
Function  
VDDO[0]  
Power  
69  
12  
42  
62  
68  
20  
44  
61  
Pad ring power pins (VDDO[3:0]).  
These pins must be connected to a  
common, well decoupled +5 VDC  
supply together with the VDDI[1:0]  
pins. Care must be taken to avoid  
coupling noise induced on the VDDO  
pins into the VDDI pins.  
VDDO[1]  
VDDO[2]  
VDDO[3]  
VDDI[0]  
VDDI[1]  
Power  
11  
49  
19  
51  
Core power pins (VDDI[1:0]).These  
pins must be connected to a common,  
well decoupled +5 VDC supply  
together with the VDDO[3:0] pins.  
VSSO[0]  
VSSO[1]  
VSSO[2]  
VSSO[3]  
Ground 70  
1
Pad ring ground pins (VSSO[3:0]).  
These pins must be connected to a  
common ground together with the  
VSSI[1:0] pins. Care must be taken to  
avoid coupling noise induced on the  
VSSO pins into the VSSI pins.  
9
17  
43  
60  
38  
58  
VSSI[0]  
VSSI[1]  
Ground 10  
50  
18  
52  
Core ground pins (VSSI[1:0]).These  
pins must be connected to a common  
ground together with the VSSO[3:0]  
pins.  
Notes on Pin Description:  
1. VDDI and VSSI are the +5 V and ground connections, respectively, for the  
core circuitry of the device. VDDO and VSSI are the +5 V and ground  
connections, respectively, for the pad ring circuitry of the device. TAVD and  
TAVS are the +5 V and ground connections, respectively, for the transmit  
analog circuitry of the device. These power supply connections must all be  
utilized and must all connect to a common +5 V or ground rail, as appropriate.  
There is no low impedance connection within the PM6341 between the core,  
pad ring, and transmit analog supply rails. Failure to properly make these  
connections may result in improper operation or damage to the device. Care  
must be taken to avoid coupling of noise into the transmit analog supply rails.  
2. RAVD and RAVS are the +5 V and ground connections, respectively, for the  
receive analog circuitry of the device. These power supply connections need  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  