PM6341 E1XC
DATA SHEET
PMC-910419
ISSUE 8
E1 FRAMER/TRANSCEIVER
Register 4B: Far End Block Error Count MSB
Bit
Type
Function
Default
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Unused
Unused
Unused
Unused
Unused
Unused
FEBE[9]
FEBE[8]
X
X
X
X
X
X
X
X
R
R
These registers indicate the number of far end block error events that occurred
during the previous accumulation interval. The FEBE counts are suppressed
when the FRMR has lost frame alignment (OOF in the FRMR Framing Status
register is set).
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE