PM6341 E1XC
DATA SHEET
PMC-910419
ISSUE 8
E1 FRAMER/TRANSCEIVER
Register Register 16H: XPLS Block CODE Indirect Address
Bit
Type
Function
Default
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Unused
Unused
Unused
Unused
Unused
CRA2
X
X
X
X
X
0
R/W
R/W
R/W
CRA1
0
CRA0
0
This register allows software to select any one of the eight internal waveform
CODE registers, addressed by the CRA[2:0] bits, for subsequent access through
the CODE Indirect Data register. When accessing the internal CODE registers,
the address of the desired register must first be written to this register.Then, by
reading or writing the Indirect Data register (Register 17H), the microprocessor
can either read from or write to the internal register identified by the CRA[2:0]
bits.
The CRA[2:0] bits address the internal registers as follows:
Table 4
CRA2
- XPLS Code Register Memory Map
CRA1
CRA0
Internal Code Register
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
CODE register #0 - first code applied
CODE register #1
CODE register #2
CODE register #3
CODE register #4
CODE register #5
CODE register #6
CODE register #7 - last code applied
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
111