欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM5381 参数 Datasheet PDF下载

PM5381图片预览
型号: PM5381
PDF下载: 下载PDF文件 查看货源
内容描述: SATURN用户网络接口,用于2488 Mbit / s的 [SATURN USER NETWORK INTERFACE FOR 2488 MBIT/S]
分类和应用: 网络接口
文件页数/大小: 487 页 / 2424 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM5381的Datasheet PDF文件第39页浏览型号PM5381的Datasheet PDF文件第40页浏览型号PM5381的Datasheet PDF文件第41页浏览型号PM5381的Datasheet PDF文件第42页浏览型号PM5381的Datasheet PDF文件第44页浏览型号PM5381的Datasheet PDF文件第45页浏览型号PM5381的Datasheet PDF文件第46页浏览型号PM5381的Datasheet PDF文件第47页  
PMC-Sierra, Inc.  
PRELIMINARY  
PM5381 S/UNI-2488  
DATASHEET  
PMC-2000489  
ISSUE 1  
SATURN USER NETWORK INTERFACE FOR 2488 MBIT/S  
Pin Name  
Type  
Pin  
No.  
Function  
OOF  
Output  
AH27 The active high out of frame (OOF) signal indicates when an  
out of frame condition is declared by the framing block.  
OOF is set high while the framing block is out of frame. An  
out of frame condition is declared when four consecutive  
errored framing patterns (A1 and A2 bytes) have been  
detected. OOF is set low while the framing block is in frame.  
OOF is updated on the rising edge of RCLK.  
The section alarm (SALM) signal is set high when an out of  
frame (OOF), loss of signal (LOS), loss of frame (LOF), line  
alarm indication signal (LAIS), line remote defect indication  
(LRDI), section trace identifier mismatch (TIM-S), section  
trace identifier unstable (TIU-S), signal fail (SF) or signal  
degrade (SD) alarm is detected. Each alarm indication can  
be independently enabled using bits in the S/UNI-2488 SARC  
Section SALM Enable registers. SALM is set low when none  
of the enabled alarms are active.  
SALM  
Output  
AG26  
SALM is updated on the rising edge of RCLK.  
RALM  
Output  
AK28 The Receive Alarm (RALM) signal is a multiplexed output of  
individual alarms of the receive path. Each alarm represents  
the logical OR of the SALM, LOP-P, AIS-P, RDI-P, ERDI-P,  
LOPC-P, PAISC-P, UNEQ-P, PSLU, PSLM, PDI-P, TIU-P, TIM-  
P status of the path. The selection of alarms to be reported is  
controlled by the S/UNI-2488 SARC Path RALM Enable  
registers.  
RALM is updated on the falling edge of ROHCLK.  
Please refer to the individual alarm interrupt descriptions and  
Functional Description Section for more details on each alarm.  
CSUCLKO  
CSUCLKI  
CRUCLKO  
Output  
Input  
AG22 This clock is used for PMC test purposes only. It must be left  
as a no connect (NC) during the normal mode of operation.  
AK24 This clock is used for PMC test purposes only. It must be tied  
to VSS during the normal mode of operation.  
Output  
AJ23  
This clock is used for PMC test purposes only. It must be left  
as a no connect (NC) during the normal mode of operation.  
Proprietary and Confidentail to PMC-Sierra Inc., and for its Customer’s Internal Use  
22  
 复制成功!