PMC-Sierra, Inc.
PRELIMINARY
PM5381 S/UNI-2488
DATASHEET
PMC-2000489
ISSUE 1
SATURN USER NETWORK INTERFACE FOR 2488 MBIT/S
Register 020B: RHPP STS-1/STM-0 #1 Error Monitor Status
Bit
Type
Function
Default
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Unused
PERDIV
PRDIV
Bit 8
Bit 7
Bit 6
R
R
R
R
R
R
X
X
X
X
X
X
Bit 5
Bit 4
PPDIV
Bit 3
PUNEQV
PPLMV
PPLUV
Unused
Bit 2
Bit 1
Bit 0
PPLUV:
The path payload label unstable status (PPLUV) bit indicates the current status of the PLU-P
defect.
Algorithm 1: PPLUV is set to logic 0.
Algorithm 2: PPLUV is set to logic 1 when a total of 5 received PSL differs from the previously
received PSL without any persistent PSL in between. PPLUV is set to logic 0
when a persistent PSL is found. A persistent PSL is found when the same PSL is
received for 3 or 5 consecutive frames.
PPLMV:
The path payload label mismatch status (PPLMV) bit indicates the current status of the PLM-
P defect.
Algorithm 1: PPLMV is set to logic 1 when the received PSL does not match, according to
Table 1, the expected PSL for 3 or 5 consecutive frames (selectable with the
PSL5 register bit). PPLMV is set to logic 0 when the received PSL matches,
according to Table 1, the expected PSL for 3 or 5 consecutive frames.
Proprietary and Confidentail to PMC-Sierra Inc., and for its Customer’s Internal Use
209