PMC-Sierra, Inc.  
PRELIMINARY  
PM5381 S/UNI-2488  
DATASHEET  
PMC-2000489  
ISSUE 1  
SATURN USER NETWORK INTERFACE FOR 2488 MBIT/S  
Z2REGEN:  
The Z2 register enable (Z2REGEN) bit controls the insertion of Z2 growth bytes in the data  
stream. When Z2REGEN is set to logic 1, the Z2 byte from the TRMP Transmit Z2 and E2  
register is inserted in the Z2 bytes according to the priority of Table 4. When Z2REGEN is set  
to logic 0, the Z2 byte from the TRMP Transmit Z2 and E2 register is not inserted.  
E2REGEN:  
The E2 register enable (E2REGEN) bit controls the insertion of line order wire in the data  
stream. When E2REGEN is set to logic 1, the line order wire from the TRMP Transmit Z2  
and E2 register is inserted in the E2 byte of STS-1/STM-0 #1 according to the priority of Table  
4. When E2REGEN is set to logic 0, the line order wire from the TRMP Transmit Z2 and E2  
register is not inserted.  
NATIONALEN:  
The national enable (NATIONALEN) bit controls the insertion of national bytes in the data  
stream. When NATIONALEN is set to logic 1, an all one or an all zero pattern is inserted in  
the national bytes according to the priority of Table 4. When NATIONALEN is set to logic 0,  
no pattern is inserted. The Z0DEF bit in the TRMP Configuration register defines the national  
bytes of ROW #1.  
NATIONALV:  
The national value (NATIONALV) bit controls the value inserted in the national bytes. When  
NATIONALV is set to logic 1, an all one pattern is inserted in the national bytes if enable via  
the NATIONALEN register bit. When NATIONALV is set to logic 0, an all zero pattern is  
inserted in the national bytes if enable via the NATIONALEN register bit.  
UNUSEDEN:  
The unused enable (UNUSEDEN) bit controls the insertion of unused bytes in the data  
stream. When UNUSEDEN is set to logic 1, an all one or an all zero pattern is inserted in the  
unused bytes according to the priority of Table 4. When UNUSEDEN is set to logic 0, no  
pattern is inserted.  
UNUSEDV:  
The unused value (UNUSEDV) bit controls the value inserted in the unused bytes. When  
UNUSEDV is set to logic 1, an all one pattern is inserted in the unused bytes if enable via the  
UNUSEDEN register bit. When UNUSEDV is set to logic 0, an all zero pattern is inserted in  
the unused bytes if enable via the UNUSEDEN register bit.  