PMC-Sierra, Inc.  
PRELIMINARY  
PM5381 S/UNI-2488  
DATASHEET  
PMC-2000489  
ISSUE 1  
SATURN USER NETWORK INTERFACE FOR 2488 MBIT/S  
Register 0001H: S/UNI-2488 Master Reset, Configuration, and Loopback  
Bit  
Type  
Function  
Default  
Bit 15  
R/W  
R/W  
R/W  
R/W  
R/W  
DRESET  
ARESET  
TXDINV  
RXDINV  
DISCOR  
Unused  
Unused  
Unused  
Unused  
PL3EN  
MODE[1]  
MODE[0]  
LOOPT  
PDLE  
0
0
0
0
1
X
X
X
X
0
0
0
0
0
0
0
Bit 14  
Bit 13  
Bit 12  
Bit 11  
Bit 10  
Bit 9  
Bit 8  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
SDLE  
SLLE  
This register allows the configuration of S/UNI-2488 features.  
SLLE:  
The SLLE bit enables the S/UNI-2488 line loopback mode when the device is configured for  
2488.32 Mbit/s serial line interface mode of operation. When SLLE is a logic one, the  
recovered data from the receive serial RXD+/- differential inputs is mapped to the TXD+/-  
differential outputs. The SDLE and the SLLE bits should not be set high simultaneously.  
SDLE:  
The SDLE bit enables the serial diagnostic loopback. When SDLE is a logic one, the transmit  
serial stream on the TXD+/- differential outputs is internally connected to the received serial  
RXD+/- differential inputs. The SDLE and the SLLE bits should not be set high  
simultaneously.  
PDLE:  
The Parallel Diagnostic Loopback, PDLE bit enables the S/UNI-2488 diagnostic loopback  
where the TRMP block is directly connected to its RRMP block. When PDLE is logic one,  
loopback is enabled. Under this operating condition, the S/UNI-2488 continues to operates  
Proprietary and Confidentail to PMC-Sierra Inc., and for its Customer’s Internal Use  
99