PM5363 TUPP+622
TUPP+622
DATASHEET
PMC-1981421
ISSUE 4
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR FOR 622 MBIT/S
INTERFACES
interrupt output will not be activated. Interrupts disabled at tributary path
overhead processor #3 will not be reported by the RTOP3I bit.
RTTB1E:
RTTB1E is the interrupt enable bit for tributary trace buffer #1 in the STP.
Interrupts enabled at tributary trace buffer #1 but masked by RTTB1E will still
be reported by the RTTB1I bit, although the interrupt output will not be
activated. Interrupts disabled at tributary trace buffer #1 will not be reported
by the RTTB1I bit.
RTTB2E:
RTTB2E is the interrupt enable bit for tributary trace buffer #2 in the STP.
Interrupts enabled at tributary trace buffer #2 but masked by RTTB2E will still
be reported by the RTTB2I bit, although the interrupt output will not be
activated. Interrupts disabled at tributary trace buffer #2 will not be reported
by the RTTB2I bit.
RTTB3E:
RTTB3E is the interrupt enable bit for tributary trace buffer #3 in the STP.
Interrupts enabled at tributary trace buffer #3 but masked by RTTB3E will still
be reported by the RTTB3I bit, although the interrupt output will not be
activated. Interrupts disabled at tributary trace buffer #3 will not be reported
by the RTTB3I bit.