PM5363 TUPP+622
TUPP+622
DATASHEET
PMC-1981421
ISSUE 4
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR FOR 622 MBIT/S
INTERFACES
Register 0CH: STP RTOP #1 and RTTB #1 Configuration
Bit
Type
Function
Default
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
R/W
R/W
ALGO2
PER5
0
0
X
X
0
0
0
1
Unused
Unused
RDI10
PDI[2]
PDI[1]
PDI[0]
R/W
R/W
R/W
R/W
This register configures the operation of RTOP #1 and RTTB #1 in the STP.
PDI[2:0]:
The PDI[2:0] bits specifies the code used to convey tributary path defect
indication (PDI-V) in the V5 byte (out of TU3 mode) or the C2 byte (in TU3
mode). For TU3 payloads, the PDI[2] bit is sign extended to form the byte
value used for the PDI-V detection.
RDI10:
The RDI10 bit controls the number of times the tributary path RDI, RFI or the
extended RDI code is filtered before being accepted. When RDI10 is set high,
the RDI bit, the RFI bit or the extended RDI code is filtered for ten
occurrences. When RDI10 is set low, the RDI bit, the RFI bit or the extended
RDI code is filtered for five occurrences.
PER5:
The PER5 bit controls the number of identical tributary path trace messages
needed for the message to become accepted. When PER5 is set high, a
messages is accepted when it is received unchanged five times. When PER5
is set low, the message is accepted after three identical repetitions.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
144