欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM5362-RI 参数 Datasheet PDF下载

PM5362-RI图片预览
型号: PM5362-RI
PDF下载: 下载PDF文件 查看货源
内容描述: SONET / SDH支路单元荷载处理器/性能监控 [SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR]
分类和应用: 监控监视器
文件页数/大小: 354 页 / 1028 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM5362-RI的Datasheet PDF文件第72页浏览型号PM5362-RI的Datasheet PDF文件第73页浏览型号PM5362-RI的Datasheet PDF文件第74页浏览型号PM5362-RI的Datasheet PDF文件第75页浏览型号PM5362-RI的Datasheet PDF文件第77页浏览型号PM5362-RI的Datasheet PDF文件第78页浏览型号PM5362-RI的Datasheet PDF文件第79页浏览型号PM5362-RI的Datasheet PDF文件第80页  
PM5362TUPP-PLUS  
DATA SHEET  
PMC-951010  
ISSUE 6  
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR  
8.5.2 Timing Generator  
The timing generator identifies the incoming tributary being processed at any  
given point in time. Based on the configuration of the RTTB (it can process  
various mixes of tributary types), the incoming timing generator extracts the STS-  
1 SPE, VC3, or a single TUG3 from a VC4, and identifies the bytes within these  
envelopes that correspond to various types of overhead and those that carry  
specific tributaries to be processed. The identification of specific tributaries  
allows the alarm monitor and extract blocks to be time-sliced across the mix of  
tributaries present in the incoming data stream.  
8.5.3 Extract  
The extract block is a time-sliced state machine. It uses timing information from  
the timing generator block to extract the tributary path trace message bytes (J2)  
from all the processed tributaries in the incoming stream. Each tributary in the  
incoming stream is allocated an individual receive buffer in the buffer block. The  
length of the message and, consequently, the depth of the corresponding buffer  
are register programmable to be 16 or 64 bytes. Bytes in the message may be  
written to the corresponding buffer in a circular fashion or optionally be  
synchronized to the framing pattern embedded in the message. For a 16 byte  
message, the first byte is identified by a logic one in the most significant bit. For  
a 64 byte message, the last two bytes are set to the ASCII characters of  
carriage-return (0DH) and linefeed (0AH).  
8.5.4 Alarm Monitor  
The alarm monitor block is a time-sliced state machine. It relies on the timing  
generator block to identify the tributary being processed. The alarm monitor  
block accesses an individual capture and expected buffers in the buffer block for  
each tributary in the incoming stream. It also monitors the received message for  
consistency. When the identical message is received three or five times, as  
controlled by the PER5 register bit, the message is accepted. This accepted  
message is then compared with the expected message provision in the buffer  
block. If the accepted message differs from the expected message, the trail trace  
identifier mismatch (TIM) alarm is raised. TIM alarm is negated if the accepted  
and expected messages match. An accepted message that contains all-zero  
bytes is treated specially. If the expected messages is not also all-zeros, the TIM  
alarm is not affected upon accepting of an all-zero message. If the expected  
message is all-zeros, accepting an all-zeros message would negate TIM.  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  
56  
 复制成功!