STANDARD PRODUCT
PM4328 TECT3
DATASHEET
PMC-2011596
ISSUE 1
HIGH DENSITY T1/E1 FRAMER
AND M13 MULTIPLEXER
compatibility with existing PMC devices is optimized. The resulting register
organization splits into sections: Master configuration registers, 28 sets of T1/E1
Framer registers, DS3 M13 multiplexing registers and SBI registers.
On power up reset the TECT3 defaults to 28 T1 framers multiplexed into the M13
multiplexer using the DS3 M23 multiplex format. For proper operation some
register configuration is necessary. System side access defaults to the SBI bus
without any tributaries enabled which will leave the SBI Drop bus tristated. By
default interrupts will not be enabled, automatic alarm generation is disabled, a
dual rail DS3 LIU interface is expected and an external transmit reference clock
is required.
Table 2: Register Memory Map
Address
Register
0000H
0001H
0002H
0003H
0004H
0005H
Global Reset
Global Configuration
Revision/Global PMON Update
Master Recovered Clock#1/Reference Clock Select
Recovered Clock#2 Select
Master Common Egress Serial and H-MVIP Interface
Configuration
0006H
Master Common Ingress Serial and H-MVIP Interface
Configuration
0007H-
000FH
Reserved
00010H
0011H
0012H
0013H
0014H
Master Clock Monitor #1
Master Clock Monitor #2
Master Clock Monitor #3
Master Clock Monitor #4
Master Clock Monitor #5
Reserved
0015H-
001FH
0020H
0021H
Master Interrupt Source
Master Interrupt Status T1/E1 #1-8
PROPRIETARY AND CONFIDENTIAL
99