Philips Semiconductors  
Product specification  
4-bit parallel access shift register  
74HC/HCT195  
by the state of the parallel load enable (PE) input. Serial  
data enters the first flip-flop (Q0) via the J and K inputs  
when the PE input is HIGH and shifted one bit in the  
direction Q0 Q1 Q2 Q3 following each  
LOW-to-HIGH clock transition. The J and K inputs provide  
the flexibility of the JK type input for special applications  
and by tying the pins together, the simple D-type input for  
general applications. The “195” appears as four common  
clocked D flip-flops when the PE input is LOW.  
FEATURES  
Asynchronous master reset  
J, K, (D) inputs to the first stage  
Fully synchronous serial or parallel data transfer  
Shift right and parallel load capability  
Complement output from the last stage  
Output capability: standard  
ICC category: MSI  
After the LOW-to-HIGH clock transition, data on the  
parallel inputs (D0 to D3) is transferred to the respective  
Q0 to Q3 outputs. Shift left operation (Q3 Q2) can be  
achieved by tying the Qn outputs to the Dn-1 inputs and  
holding the PE input LOW.  
GENERAL DESCRIPTION  
The 74HC/HCT195 are high-speed Si-gate CMOS devices  
and are pin compatible with low power Schottky TTL  
(LSTTL). They are specified in compliance with JEDEC  
standard no. 7A.  
All parallel and serial data transfers are synchronous,  
occurring after each LOW-to-HIGH clock transition.  
There is no restriction on the activity of the J, K, Dn and  
PE inputs for logic operation other than the set-up and  
hold time requirements. A LOW on the asynchronous  
master reset (MR) input sets all Q outputs LOW,  
independent of any other input condition.  
The 74HC/HCT195 performs serial, parallel,  
serial-to-parallel or parallel-to-serial data transfer at very  
high speeds. The “195” operates on two primary modes:  
shift right (QoQ1) and parallel load, which are controlled  
QUICK REFERENCE DATA  
GND = 0 V; Tamb = 25 °C; tr = tf = 6 ns  
TYPICAL  
SYMBOL  
tPHL/ tPLH  
PARAMETER  
CONDITIONS  
UNIT  
ns  
HC  
15  
HCT  
15  
propagation delay CP to Qn  
maximum clock frequency  
input capacitance  
CL = 15 pF; VCC = 5 V  
fmax  
CI  
57  
57  
MHz  
pF  
3.5  
105  
3.5  
105  
CPD  
power dissipation capacitance per package  
notes 1 and 2  
pF  
Notes  
1. CPD is used to determine the dynamic power dissipation (PD in µW):  
PD = CPD × VCC2 × fi + ∑ (CL × VCC2 × fo)  
where:  
fi = input frequency in MHz  
fo = output frequency in MHz  
(CL × VCC2 × fo) = sum of outputs  
CL = output load capacitance in pF  
VCC = supply voltage in V  
2. For HC the condition is VI = GND to VCC  
For HCT the condition is VI = GND to VCC 1,5 V  