Head-separated Digital Pressure Sensor
DP5
SERIES
DPH
SERIES
730
FIBER
SENSORS
I/O CIRCUIT DIAGRAMS
DP5-C
I/O circuit diagram
Terminal No.
D
2
Sensor head main circuit
1
1
Type setting /
indicator
signal
4
4
Analog
voltage
input
+V
D
1
Controller main circuit
Terminal No.
Color code of cable with connector
1
6
1k
Z
D1
Tr
1
Tr
2
Z
D3
Z
D2
(Brown) +V
(Pink) External
input (Note)
Main circuit
D
NPN output type
For independent use of Sensor head
Terminal No.
Color code
(Brown) +V
(White) Not connected
(Note1)
(Black) Analog +
voltage output
(1 to 5 V)
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
1k
Z
D4
2
2
3
Sensor head
internal circuit
0V
3
(Gray) Analog
2 voltage output
Load
(Black) Comparative
Load +
Output 1
4
100 mA max.
(White)
Comparative Output 2
5
100 mA max.
(Blue) 0 V
3
Users’ circuit
12 to 24 V DC
+10
–15
%
12 to 24 V DC
+
10
%
15
1k
Z
D
(Blue) 0 V
Sensor head
internal circuit
Users’ circuit
Intermediate cable
Controller internal circuit
Note: Select and use the auto-reference function and remote zero-adjustment function.
Symbols … D
1
, D
2
: Reverse supply polarity protection diode
Z
D1
to Z
D4
: Surge absorption zener diode
Tr
1
, Tr
2
: NPN output transistor
Notes: 1) In case the sensor head is used independently, insulate
the white lead wire (terminal No.4) and keep it open.
2) When the sensor head is used independently, devices
connected to the analog output must have an input
impedance set at 50kΩ or more.
Symbols … D : Reverse supply polarity protection diode
Z
D
: Surge absorption zener diode
Terminal arrangement diagram
Connector for sensor
head connection
Connector for power supply /
I-O cable connection
1
2
3
4
5
6
Connector for sensor
head connection
1
2
3
4
3
1
2
4
1 2 3 4 5 6
Connector for power supply /
I-O cable connection
+V
Analog voltage output
0V
Comparative Output 1
Comparative Output 2
External input (Auto-reference /
Remote zero-adjustment function)
+V
Analog voltage output
0V
Not connected
DP5-C-P
I/O circuit diagram
Terminal No.
+V
D
2
Sensor head main circuit
Type setting /
indicator
signal
Analog
voltage
input
D
1
Z
D1
Tr
2
1k
Z
D3
Z
D2
Terminal No.
Color code of cable with connector
(Brown) +V
(Pink) External
input (Note)
(Black) Comparative
100 mA max.
Output 1
100 mA max.
(White)
Comparative Output 2
(Gray) Analog
voltage output
(Blue) 0 V
Users’ circuit
Load
Load
D
PNP output type
For independent use of Sensor head
Terminal No.
Color code
(Brown) +V
(White) Not connected
(Note1)
(Black) Analog +
voltage output
(1 to 5 V)
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Controller main circuit
1k
Z
D4
Tr
1
+
12 to 24 V DC
+10
–15
%
Main circuit
12 to 24 V DC
+10
–15
%
1k
Z
D
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other
Products
0V
(Blue) 0 V
Sensor head
internal circuit
Users’ circuit
Sensor head
Controller internal circuit
internal circuit Intermediate cable
Note: Select and use the auto-reference function and remote zero-adjustment function.
Symbols … D
1
, D
2
: Reverse supply polarity protection diode
Z
D1
to Z
D4
: Surge absorption zener diode
Tr
1
, Tr
2
: PNP output transistor
Notes: 1) In case the sensor head is used independently, insulate
the white lead wire (terminal No.4) and keep it open.
2) When the sensor head is used independently, devices
connected to the analog output must have an input
impedance set at 50kΩ or more.
Symbols … D: Reverse supply polarity protection diode
Z
D
: Surge absorption zener diode
Terminal arrangement diagram
Connector for sensor
head connection
Connector for power supply /
I-O cable connection
1
2
3
4
5
6
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
DP5/
DPH
Connector for sensor
head connection
1
2
3
4
3
1
2
4
1 2 3 4 5 6
Connector for power supply /
I-O cable connection
+V
Analog voltage output
0V
Comparative Output 1
Comparative Output 2
External input (Auto-reference /
Remote zero-adjustment function)
+V
Analog voltage output
0V
Not connected