Head-separated Digital Pressure Sensor DP5SERIES DPHSERIES
733
FIBER
PRECAUTIONS FOR PROPER USE
Refer to General precautions.
SENSORS
LASER
Remote zero-adjustment function
Forced output mode
SENSORS
PHOTO-
ELECTRIC
SENSORS
• The remote zero-adjustment function forcibly displays the
pressure value at the time of application of an external
input signal to zero. Please select the remote zero-
adjustment function at the supplementary setting mode
when using this function.
• In the initial setting mode, if the output mode is set to the
forced output mode ( ), the comparative outputs are
forcibly maintained at OFF level in the sensing mode,
irrespective of Set Values P-1 to P-4.
Further, if the keys are operated as per the procedure
given below, the comparative outputs can be forcibly
switched either ON or OFF without applying pressure
at the pressure port. This is convenient for an operation
check of the comparative outputs or for an inspection
before commencing work.
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
• At the time of remote zero-adjustment input, the set
values are not corrected. When using the remote zero-
adjustment function, make sure that the pressure and
the set values do not exceed the rated pressure range.
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Operation chart
Peak hold & bottom hold functions
<Normal operation (comparative outputs set to NO)>
PARTICULAR
USE
• Peak hold and bottom hold functions enable the display
of the peak value (maximum pressure value) and the
bottom value (minimum pressure value) of the varying
measured pressure.
These functions are convenient for finding the pressure
variation range or determining the reference for pressure
settings.
SENSORS
ON
Comparative
Output 1
OFF
ON
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Comparative
Output 2
OFF
WIRE-SAVING
SYSTEMS
Applied
0
1
1
0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 00
0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 00
-1 P-2 P-3 P-4
pressure (kPa)
• Please note that the peak value and the bottom value
data is erased when it is no longer displayed.
Display value (kPa)
0
MEASURE-
MENT
SENSORS
P
Set value (kPa)
1
0 2 0 3 0 4 0
STATIC
CONTROL
DEVICES
Others
<With remote zero-adjustment input (comparative outputs set to NO)>
ENDOSCOPE
Remote zero-adjustment input: 50 kPa
Output mode: Hysteresis mode
• Use within the rated pressure range.
• Do not apply pressure exceeding the pressure
withstandability value. The diaphragm will get damaged
and correct operation shall not be maintained.
LASER
MARKERS
ON
Comparative
Output 1
OFF
PLC /
TERMINALS
• Do not use during the initial transient time (DP5: 3 sec.
approx., DPH: 50 ms approx.) after the power supply is
switched on.
ON
HUMAN
MACHINE
Comparative
Output 2
OFF
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
• Avoid dust, dirt, and steam.
Applied
0
10 20 30 40 50 60 70 80 90 100
pressure (kPa)
• Take care that the sensor does not come in direct contact
with water, oil, grease, or organic solvents, such as,
thinner, etc.
Display value (kPa)
−50 −40 −30 −20 −10
0
10 20 30 40 50
-1 P-2 P-3 P-4
FA
COMPONENTS
P
1
Set value (kPa)
0
20 30 40
MACHINE
VISION
• Do not insert wires, etc., into the pressure port. The
diaphragm will get damaged and correct operation shall
not be maintained.
SYSTEMS
Note: As in the case of the hysteresis mode, the displayed values and the ON / OFF points of the
output are shifted also in case the output mode is set to the window comparator mode.
UV
CURING
SYSTEMS
Remote zero-adjustment input: 50 kPa
Output mode: Leak test mode
• Do not operate the keys with pointed or sharp objects.
ON
Key-protect function
Comparative
Selection
Guide
Output 1
OFF
ON
• Key-protect is a function which prevents any unintentional
change in the conditions which have been entered in each
setting mode by making the sensor not to respond to the
key operations.
Pressure/
Digital Display
Comparative
Output 2
Pressure/
Head-separated
OFF
Flow
Applied
Other
Products
0
10 20 30 40 50 60 70 80 90 100
pressure (kPa)
• Since the key-protect information is stored in an
EEPROM, it is not erased even if the power supply is
switched off.
−50 −40 −30 −20 −10
0
10 20 30 40 50
P-3 P-4
Display value (kPa)
P
1
-1 P-2
20
DPC-L100/
DPH-L100
Set value (kPa)
0
30
40
DPS-400/
• Please take care to remember if the key-protect
function has been set.
• When the keys are to be operated, make sure that key-
protect is released.
Note: In the leak test mode, the zero-adjustment function is applied only to Comparative Output 2.
DPH-100
DPC-100/
DPH-100
DP5/
DPH
Comparative Output 1 operates with the atmospheric pressure as the reference.
• Maintain the pressure at a constant level for at least 2 ms after the
remote zero-adjustment input is made Low (High in case of PNP output
type). If used in a transient state, it will result in wrong operation.
• Use the comparative outputs at least “set response time
+ 2 ms” after the remote zero-adjustment input is made Low (High in
case of PNP output type).
• At the time of remote zero-adjustment input,
is displayed on the
3 1/2 digit display for 1 sec. approx.
• If the power supply is switched off and then on again, the remote zero-
adjustment input value (set Value P-A) is cleared and the sensor returns
to normal operation with atmospheric pressure as the reference.