欢迎访问ic37.com |
会员登录 免费注册
发布采购

DPH-A00 参数 Datasheet PDF下载

DPH-A00图片预览
型号: DPH-A00
PDF下载: 下载PDF文件 查看货源
内容描述: 头部分离数字压力传感器DP5系列DPH系列 [Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES]
分类和应用: 传感器压力传感器
文件页数/大小: 14 页 / 1528 K
品牌: PANASONICBATTERY [ Panasonic Battery Group ]
 浏览型号DPH-A00的Datasheet PDF文件第3页浏览型号DPH-A00的Datasheet PDF文件第4页浏览型号DPH-A00的Datasheet PDF文件第5页浏览型号DPH-A00的Datasheet PDF文件第6页浏览型号DPH-A00的Datasheet PDF文件第8页浏览型号DPH-A00的Datasheet PDF文件第9页浏览型号DPH-A00的Datasheet PDF文件第10页浏览型号DPH-A00的Datasheet PDF文件第11页  
729
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Head-separated Digital Pressure Sensor
DP5
SERIES
DPH
SERIES
SPECIFICATIONS
Controller
Type
Item
Model No.
Applicable sensor head
Rated pressure range (Note 2)
Set pressure range (Note 2)
Supply voltage / Current consumption
Sensor supply voltage
NPN output type
DP5-C
PNP output type
DP5-C-P
DPH-A00, DPH-A02, DPH-A07, DPH-A10, DPH-A12, DPH-A17, DPH-A20, DPH-A22, DPH-A27, DPH-A30
Vacuum pressure: 0 to –101.3 kPa, Positive pressure: 0 to 1.000 MPa, Compound pressure: –100.0 to 100.0 kPa
Vacuum pressure: 101.3 to –101.3 kPa (1.033 to –1.033 kgf/cm
2
, 14.70 to –14.70 psi, 1.013 to –1.013 bar, 760 to –760 mmHg, 29.9 to –29.9 inHg)
Positive pressure: –1.050 to 1.050 MPa (–10.71 to 10.71 kgf/cm
2
, –152.2 to 152.2 psi, –10.50 to 10.50 bar)
Compound pressure: –199.9 to 199.9 kPa (–2.038 to 2.038 kgf/cm
2
, –28.99 to 28.99 psi, –1.999 to 1.999 bar, –1499 to 1499 mmHg, –59 to 59 inHg)
12 to 24 V DC
+10
% Ripple P-P 10 % or less / 60 mA or less (not including sensor head)
–15
Same as supply voltage
NPN open-collector transistor (2 outputs)
Maximum sink current: 100 mA
Applied voltage: 30 V DC or less
(between comparative output and 0 V)
Residual voltage: 1 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
PNP open-collector transistor (2 outputs)
Maximum source current: 100 mA
Applied voltage: Same as supply voltage
(between comparative output and +V)
Residual voltage: 2 V or less (at 100 mA source current)
Comparative outputs
(Comparative Output 1, 2)
Utilization category
Output operation
Output modes
Hysteresis
Repeatability
Response time
Short-circuit protection
Sensor head input
External input
Auto-reference / Remote
zero-adjustment function
Inputs
DC-12 or DC-13
NO / NC, selectable by key operation
Equipped with 4 types of modes: hysteresis mode, window comparator mode, leak test mode,
forced output mode (selectable by key operation)
1 digit (however, variable in hysteresis mode, variable for Comparative Output 1 only when using leak test mode)
With vacuum / positive pressure type sensor head: within ±0.2 % F.S. ±1 digit (±3 digits)
With compound pressure type sensor head: within ±0.2 % F.S. ±2 digits (±6 digits)
1 ms, 16 ms, 128 ms, 512 ms or less, selectable by key operation
(however, set response time is + 2 ms when auto-reference / remote zero-adjustment input is applied)
Incorporated
Input voltage range: 1 to 5 V DC (over rated pressure range)
Input condition: NPN non-contact input
[operates in Low (fall) state]
Signal condition: High...5 to 30 V, or open
Low....0.4 V or less
Low level input time...2 ms or more
Output voltage: 1 to 5 V DC (over rated pressure range)
Zero point: within 1 V ± 2.5 % F.S.
(vacuum / positive pressure type)
within 3 V ±3.5 % F.S. (compound pressure type)
Span: within 4 V ±4 % F.S.
Linearity: within ±1 % F.S.
Output impedance: 1 kΩ approx.
Input condition: PNP non-contact input
[operates in High (rise) state]
Signal condition: High...5 to 30 V
Low....0.4 V or less, or open
High level input time...2 ms or more
5
Output voltage (V)
3
1
Pressure
High pressure
positive / compound
pressure type
High vacuum
(vacuum pressure type)
Analog voltage output
(
)
Display
Displayable pressure
range
Operation display
3 1/2 digit LCD display (with red and green backlight)
(Display refresh rate: 256 ms, 512 ms or 1,024 ms selectable by key operation)
Vacuum pressure: 5.1 to –101.3 kPa (0.052 to –1.033 kgf/cm
2
, 0.74 to –14.70 psi, 0.051 to –1.013 bar, 38 to –760 mmHg, 1.5 to –29.9 inHg)
Positive pressure: –0.050 to 1.050 MPa (–0.51 to 10.71 kgf/cm
2
, –7.2 to 152.2 psi, –0.50 to 10.50 bar)
Compound pressure: –101.3 to 105.0 kPa (–1.033 to 1.071 kgf/cm
2
, –14.70 to 15.22 psi, –1.013 to 1.050 bar, –760 to 787 mmHg, –29.9 to 31.0 inHg)
LCD segment is red when the comparative output is ON, and green when it is OFF (output is selected via supplementary settings)
Bar display in steps of 14 % F.S. approx.
Orange LED (lights up when the Comparative Output 1 is ON), Green LED (lights up when the Comparative Output 2 is ON)
3 (Industrial environment)
IP40 (IEC)
0 to +50 °C
+32 to +122 °F
(No dew condensation), Storage: –10 to +60 °C
+14 to +140 °F
35 to 85 % RH, Storage: 35 to 85 % RH
EN 61000-6-2, EN 61000-6-4
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm
0.030 in
amplitude, in X, Y and Z directions for two hours each
100 m/s
2
acceleration (10 G approx.) in X, Y and Z directions for three times each
Over ambient temperature range 0 to +50 °C
+32 to +122 °F:
within ±0.5 % F.S. of pressure at +25 °C
+77 °F
(not including sensor head)
Front case: ABS, LCD display section: PET, Rear case: PBT
Connector
0.16 to 0.32 mm (AWG#25 to #22) (Note 3)
2
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other
Products
Analog bar display
Operation indicator
Pollution degree
Environmental resistance
Suitable cable
Protection
Ambient temperature
Ambient humidity
EMC
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
Temperature characteristics
Material
Connecting method
Conductor cross-section area
Lead wire diameter
Wire material
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
DP5/
DPH
ø1.2 to ø1.8 mm
ø0.047 to ø0.071 in
Tin plated, soft, twisted copper wire
Total length up to 100 m
328.084 ft
(less than 10 m
32.808 ft
when conforming to CE marking) is possible with 0.3 mm
2
, or more, cable.
Net weight: 20 g approx.
Panel mounting bracket (MS-DP-1):
1 set, Connector: 1 set (Housing: 1 pc., Connector pin: 6 pcs.), Pressure unit label: 1 set., Connector cap: 1 pc.
Cable length
Weight
Accessories
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C
+68 °F.
2) The rated pressure range indicates the range for full product performance. It changes automatically according to the connected pressure sensor head.
3) If the wiring is longer than 5 m
16.404 ft,
use a cable with a diameter of 0.3 mm
2