Multilayer Ceramic Capacitors(For General Usage)
Specification
Item
Test Method
Class 1
Appearance:
Class 2
Appearance:
No mechanical damage
Capacitance change:
Temp. Char.
B, X7R, X5R: Within 20 % Charge/discharge current: 50 mA max.
F, Y5V: Within 30 %
tan :
δ
Temp. Char.
Damp Heat
Load
Preconditioning:Voltage treatment/Class 2(✽2)
Temperature:40 2 °C
Relative humidity:90 to 95 %
Applied voltage:Rated voltage
No mechanical damage
Capacitance change:
Within 7.5 % or 0.75 pF
whichever is larger.
Q:
Test period:500+24/0 h
Recovery (Standard condition)
Class 1:24 2 h
C<30 pF:Q 100+10C/3
>
30 pF C 1000 pF:Q 200
<
<
>
tan
:
B, X7R, X5R: 0.25 max.
F, Y5V: 0.3 max.
Class 2:48 4 h
δ
C>1000 pF:tan
0.004
δ<
(C:Nominal capacitance in pF) IR:
IR:
500 M or 25/C (M )
ȑ
ȑ
500 M or 25/C (M )
Whichever is less.
ȑ
ȑ
Whichever is less.
Note:5/C (M ) min. for
ȑ
(C:Nominal capacitance in µF)
DC 10 V max.
C:Nominal capacitance in µF
Please see the technical
specifications for details.
High
Temperature
Load
Appearance:
Appearance:
Preconditioning:Voltage treatment/Class 2(✽2)
Temperature:
Maximum operating temp. 3 °C
Applied voltage:
No mechanical damage
Capacitance change:
Within 3 % or 0.3 pF
whichever is larger.
Q:
No mechanical damage
Capacitance change:
Temp. Char.
B, X7R, X5R: Within 20 %
F, Y5V: Within 30 %
(1) Rated voltage ×200 %
(2) Rated voltage ×100 %
Please see the technical specifications
for details.
C<10 pF:Q 200+10C
tan :
δ
>
10 pF C 30 pF:Q 275+5C/2
Temp. Char.
<
<
>
30 pF C 1000 pF:Q 350
B, X7R, X5R: 0.25 max.
F, Y5V: 0.3 max.
Charge/discharge current: 50 mA max.
Test period:1000+48/0 h
Recovery (Standard condition)
Class 1:24 2 h
<
<
>
tan
:
δ
C>1000 pF:tan
0.004
IR:
δ<
C:Nominal capacitance in pF
1000 M or 50/C (M )
Ω
ȑ
IR:
Whichever is less.
Class 2:48 4 h
1000 M or 50/C (M )
Note:10/C (M ) min. for
DC 10 V max.
ȑ
ȑ
ȑ
Whichever is less.
C:Nominal capacitance in µF
C:Nominal capacitance in µF
Please see the technical
specifications for details.
(✽1) Heat treatment:1 h of heat treatment at 150+0/–10 °C followed by 48 4 h recovery under standard conditions
(✽2) Voltage treatment:1 h of voltage treatment under the specified temperature and voltage for testing followed by 48 4 h of recovery under
standard conditions
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.