OXCB950  
OXFORD SEMICONDUCTOR LTD.  
7.9 Automatic Flow Control  
Automatic in-band flow control, automatic out-of-band flow  
control and special character detection features can be  
used when in Enhanced mode (flow control is software  
compatible with the 16C654). Alternatively, 750-compatible  
automatic out-of-band flow control can be enabled when in  
non-Enhanced mode. In 950 mode, in-band and out-of-  
band flow controls are compatible with 16C654 with the  
addition of fully programmable flow control thresholds.  
EFR[3:2]: In-band transmit flow control mode  
When in-band transmit flow control is enabled, XON/XOFF  
character(s) are inserted into the data stream whenever the  
RFL passes the upper trigger level and falls below the  
lower trigger level respectively.  
For automatic in-band flow control, bit 4 of EFR must be  
set. The combinations of software transmit flow control can  
then be selected by programming EFR[3:2] as follows:  
7.9.1 Enhanced Features Register ‘EFR’  
logic [00] In-band transmit flow control is disabled.  
logic [01] Single character in-band transmit flow control  
enabled, using XON2 as the XON character  
and XOFF2 as the XOFF character.  
Writing 0xBF to LCR enables access to the EFR and other  
Enhanced mode registers. This value corresponds to an  
unused data format. Writing 0xBF to LCR will set LCR[7]  
but leaves LCR[6:0] unchanged. Therefore, the data format  
of the transmitter and receiver data is not affected. Write  
the desired LCR value to exit from this selection.  
logic [10] Single character in-band transmit flow control  
enabled, using XON1 as the XON character  
and XOFF1 as the XOFF character.  
logic[11] The value EFR[3:2] = “11” is reserved for  
future use and should not be used  
Note: In-band transmit and receive flow control is disabled  
in 9-bit mode.  
EFR[4]: Enhanced mode  
EFR[1:0]: In-band receive flow control mode  
logic 0 Non-Enhanced mode. Disables IER bits 4-7,  
ISR bits 4-5, FCR bits 4-5, MCR bits 5-7 and in-  
band flow control. Whenever this bit is cleared,  
the setting of other bits of EFR are ignored.  
logic 1 Enhanced mode. Enables the Enhanced Mode  
functions. These functions include enabling  
IER bits 4-7, FCR bits 4-5, MCR bits 5-7. For  
in-band flow control the software driver must  
set this bit first. If this bit is set, out-of-band flow  
control is configured with EFR bits 6-7,  
otherwise out-of-band flow control is compatible  
with 16C750.  
When in-band receive flow control is enabled, the UART  
compares the received data with the programmed XOFF  
character(s). When this occurs, the UART will disable  
transmission as soon as any current character  
transmission is complete. The UART then compares the  
received data with the programmed XON character(s).  
When  
a match occurs, the UART will re-enable  
transmission (see section 7.11.6).  
For automatic in-band flow control, bit 4 of EFR must be  
set. The combinations of software receive flow control can  
be selected by programming EFR[1:0] as follows:  
EFR[5]: Enable special character detection  
logic 0 Special character detection is disabled.  
logic 1 While in Enhanced mode (EFR[4]=1), the  
UART compares the incoming receiver data  
with the XOFF2 value. Upon a correct match,  
the received data will be transferred to the RHR  
and a level 5 interrupt (XOFF or special  
character) will be asserted if level 5 interrupts  
are enabled (IER[5] set to 1).  
logic [00] In-band receive flow control is disabled.  
logic [01] Single character in-band receive flow control  
enabled, recognising XON2 as the XON  
character and XOFF2 as the XOFF  
character.  
logic [10] Single character in-band receive flow control  
enabled, recognising XON1 as the XON  
character and XOFF1 and the XOFF  
character.  
EFR[6]: Enable automatic RTS flow control.  
logic 0 RTS flow control is disabled (default).  
logic 1 RTS flow control is enabled in Enhanced mode  
(i.e. EFR[4] = 1), where the RTS# pin will be  
forced inactive high if the RFL reaches the  
upper flow control threshold. This will be  
released when the RFL drops below the lower  
threshold. 650 and 950-mode drivers should  
use this bit to enable RTS flow control.  
logic [11] The behaviour of the receive flow control is  
dependent on the configuration of EFR[3:2].  
Single character in-band receive flow control  
is enabled, accepting XON1 or XON2 as valid  
XON characters and XOFF1 or XOFF2 as  
valid XOFF characters when EFR[3:2] = “01”  
or “10”. EFR[1:0] should not be set to “11”  
when EFR[3:2] is ‘00’.  
DS-0033 Sep 05  
External-Free Release  
Page 42  