MC10E122, MC100E122
Table 3. 10E SERIES PECL DC CHARACTERISTICS V = 5.0 V; V = 0.0 V (Note 1)
CCx
EE
0°C
25°C
Typ
85°C
Typ
Symbol
Characteristic
Power Supply Current
Min
Typ
41
Max
49
Min
Max
49
Min
Max
49
Unit
mA
mV
mV
mV
mV
mA
I
41
41
EE
V
V
V
V
Output HIGH Voltage (Note 2)
Output LOW Voltage (Note 2)
Input HIGH Voltage
3980
3050
3830
3050
4070
3210
3995
3285
4160
3370
4160
3520
200
4020
3050
3870
3050
4105
3210
4030
3285
4190
3370
4190
3520
200
4090
3050
3940
3050
4185
3227
4110
3302
4280
3405
4280
3555
200
OH
OL
IH
Input LOW Voltage
IL
I
I
Input HIGH Current
IH
IL
Input LOW Current
0.5
0.3
0.5
0.25
0.3
0.2
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
1. Input and output parameters vary 1:1 with V . V can vary −0.46 V / +0.06 V.
CC
EE
2. Outputs are terminated through a 50 ohm resistor to V − 2.0 V.
CC
Table 4. 10E SERIES NECL DC CHARACTERISTICS V = 0.0 V; V = −5.0 V (Note 3)
CCx
EE
0°C
25°C
Typ
41
85°C
Typ
41
Symbol
Characteristic
Power Supply Current
Min
Typ
Max
49
Min
Max
49
Min
Max
49
Unit
mA
mV
I
41
EE
V
V
V
V
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage
Input HIGH Current
Input LOW Current
−1020 −930
−840
−980
−895
−810
−910
−815
−720
OH
OL
IH
−1950 −1790 −1630 −1950 −1790 −1630 −1950 −1773 −1595 mV
−1170 −1005 −840 −1130 −970 −810 −1060 −890 −720 mV
−1950 −1715 −1480 −1950 −1715 −1480 −1950 −1698 −1445 mV
IL
I
I
200
200
200
mA
mA
IH
IL
0.5
0.3
0.5
0.065
0.3
0.2
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
3. Input and output parameters vary 1:1 with V . V can vary −0.46 V / +0.06 V.
CC
EE
4. Outputs are terminated through a 50 ohm resistor to V − 2.0 V.
CC
http://onsemi.com
3