内容描述: 一个理想指标的OK / NG判断在自动采摘机,测量用称重传感器信号输入因素,如压力,负载,转矩和重量。 [An Ideal Indicator for OK/NG Judgements in Automated and Picking Machines, Measuring Factors such as Pressure, Load, Torque, and Weight Using Load Cell Signal Input.]
分类和应用: 传感器
文件页数/大小: 16 页 / 1139 K
品牌: OMRON [ OMRON ELECTRONICS LLC ]
 浏览型号K34-C1的Datasheet PDF文件第8页浏览型号K34-C1的Datasheet PDF文件第9页浏览型号K34-C1的Datasheet PDF文件第10页浏览型号K34-C1的Datasheet PDF文件第11页浏览型号K34-C1的Datasheet PDF文件第12页浏览型号K34-C1的Datasheet PDF文件第13页浏览型号K34-C1的Datasheet PDF文件第14页浏览型号K34-C1的Datasheet PDF文件第16页  
K3HB-V  
Wiring Precautions  
Mounting Method  
For terminal blocks, use the crimp terminals suitable for M3 screws.  
Tighten the terminal screws to the recommended tightening torque  
of approx. 0.5 Nm.  
1. Insert the K3HB into the mounting cutout in the panel.  
2. Insert watertight packing around the Unit to make the mounting  
watertight.  
To prevent inductive noise, separate the wiring for signal lines from  
Watertight  
packing  
that for power lines.  
Wiring  
Use the crimp terminals suitable for M3 screws shown below.  
5.8 mm max.  
5.8 mm max.  
3. Insert the adapter into the grooves on the left and right sides of  
the rear case and push until it reaches the panel and is fixed in  
place.  
Unit Stickers  
Select the appropriate units from the unit sticker sheets provided  
Adapter  
and attach the sticker to the Indicator.  
LCD Field of Vision  
The K3HB is designed to have the best visibility at the angles shown  
in the following diagram.  
Note: When using for meters, such as weighing meters, use the units  
specified by regulations on weights and measures.  
10°  
30°  
Rubber Packing  
(Sold Separately)  
K32-P1  
If the rubber packing is lost or damaged, it can  
be ordered using the following model number:  
K32-P1.  
(Depending on the operating environment  
deterioration, contraction, or hardening of the  
rubber packing may occur and so, in order to  
ensure the level of waterproofing specified in  
NEMA4, periodic replacement is  
recommended.)  
Note: Rubber packing is provided with the  
Controller.  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
In the interest of product improvement, specifications are subject to change without notice.  
15  