G6B
■Characteristics
PCB Power Relay
G6B-2114P-US
G6B-2114P-FD-US
G6B-2214P-US
G6B-1114P-US
G6B-1114P-FD-US
G6B-1174P-US
G6B
Model
G6BU-1114P-US
G6BK-1114P-US
-1177P(-FD)-ND-US G6B-2214P-FD-US
G6B-2014P-US
G6B-1174P-FD-US
G6B-2014P-FD-US
Built-in operation
indicator & surge
absorption diode
Single-winding
latching
Double-winding
latching
Item
Classification Single-side stable
Single-side stable
Contact resistance *1
Operate (set) time
Release (reset) time
Min. set pulse width
Min. reset pulse width
Insulation resistance *2
30 mΩ max.
10 ms max.
10 ms max.
−
−
15 ms (at 23°C)
15 ms (at 23°C)
1,000 MΩ min.
−
−
2,000 VAC,
50/60 Hz for 1 min
Between coil and contacts
3,000 VAC, 50/60 Hz for 1 min
3,000 VAC, 50/60 Hz for 1 min
Between contacts of the same
polarity
Between contacts of different
polarity
1,000 VAC, 50/60 Hz for 1 min
Dielectric strength
2,000 VAC,
50/60 Hz for 1 min
−
250 VAC,
50/60 Hz for 1 min
Between set and reset coils
−
−
Impulse withstand voltage (between coil and contacts)
6 kV 1.2 × 50 μs
4.5 kV 1.2 × 50 μs
6 kV 1.2 × 50 μs
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
1,000 m/s2
Vibration
resistance
Shock resistance
Durability
G
6
B
100 m/s2
300 m/s2
100 m/s2
50,000,000 operations min. (at 18,000 operations/hr)
100,000 operation min. (at 1,800 operations/hr under rated load)
10 mA at 5 VDC
Failure rate (P level) (reference value) *3
Ambient operating temperature
Ambient operating humidity
Weight
-25°C to 70°C (with no icing or condensation)
5% to 85%
Approx. 3.5 to 4.6 g
Approx. 3.5 g
Approx. 3.7 g
Approx. 5.4 g
Approx. 4.5 g
Note 1. The values here are initial values.
2.The G6B-1177P(-FD)-ND model is flux-resistant. Do not wash it down with water.
*1. The contact resistance was measured with 1 A at 5 VDC using a voltage-drop method.
*2. Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was
measured.(Except the location between set/reset coil)
*3. This value was measured at a switching frequency of 120 operations/min.
4