ML9041A-01ACVWA 参数 Datasheet PDF下载

ML9041A-01ACVWA图片预览
型号: ML9041A-01ACVWA
PDF下载: 下载PDF文件 查看货源
内容描述: [Dot Matrix LCD Driver, 17 X 100 Dots, CMOS, 10.62 X 2.55 MM, GOLD BUMP, DIE-189]
分类和应用:
文件页数/大小: 64 页 / 651 K
品牌: OKI [ OKI ELECTRONIC COMPONETS ]
 浏览型号ML9041A-01ACVWA的Datasheet PDF文件第30页浏览型号ML9041A-01ACVWA的Datasheet PDF文件第31页浏览型号ML9041A-01ACVWA的Datasheet PDF文件第32页浏览型号ML9041A-01ACVWA的Datasheet PDF文件第33页浏览型号ML9041A-01ACVWA的Datasheet PDF文件第35页浏览型号ML9041A-01ACVWA的Datasheet PDF文件第36页浏览型号ML9041A-01ACVWA的Datasheet PDF文件第37页浏览型号ML9041A-01ACVWA的Datasheet PDF文件第38页  
PEDL9041A-02  
OKI Semiconductor  
ML9041A-xxA/xxB  
Instruction Codes  
An instruction code is a signal sent from the CPU to access the ML9041A. The ML9041A starts operation as  
instructed by the code received. The busy status of the ML9041A is rather longer than the cycle time of the CPU,  
since the internal processing of the ML9041A starts at a timing which does not affect the display on the LCD. In  
the busy status (Busy Flag is “1”), the ML9041A cannot input the Busy Flag Read instruction only. Therefore, the  
CPU should ensure that the Busy Flag is “0” before sending an instruction code to the ML9041A.  
1) Display Clear  
W
RS1  
1
RS0  
0
R/  
DB7  
0
DB6  
0
DB5  
0
DB4  
0
DB3  
0
DB2  
0
DB1  
0
DB0  
1
0
Instruction Code:  
When this instruction is executed, the LCD display including arbitrator display is cleared and the I/D entry  
mode is set to “Increment”. The value of “S” (Display shifting) remains unchanged. The position of the cursor  
or blink being displayed moves to the left end of the LCD (or the left end of the line 1 in the 2-line display  
mode).  
Note: All DDRAM and ABRAM data turn to “20” and “00” in hexadecimal, respectively. The value of the  
address counter (ADC) turns to the one corresponding to the address “00” (hexadecimal) of the  
DDRAM.  
The execution time of this instruction is 1.52 ms (maximum) at an oscillation frequency of 270 kHz.  
2) Cursor Home  
W
RS1  
1
RS0  
0
R/  
DB7  
0
DB6  
0
DB5  
0
DB4  
0
DB3  
0
DB2  
0
DB1  
1
DB0  
0
×
Instruction code:  
×
: Don’t Care  
When this instruction is executed, the cursor or blink position moves to the left end of the LCD (or the left end  
of line 1 in the 2-line display mode). If the display has been shifted, the display returns to the original display  
position before shifting.  
Note: The value of the address counter (ADC) goes to the one corresponding to the address “00”  
(hexadecimal) of the DDRAM).  
The execution time of this instruction is 1.52 ms (maximum) at an oscillation frequency of 270 kHz.  
34/64  