NXP Semiconductors
FXPS7115D4
Digital absolute pressure sensor, 40 kPa to 115 kPa
V
CC
V
REGA
V
V
REGA
REF
BANDGAP
VOLTAGE
REFERENCE
REGULATOR
BIAS
GENERATOR
OSCILLATOR
TRIM
TRIM
TRIM
C2V
V
REG_MOD
REFERENCE
GENERATOR
Σ
CONVERTER
OTP
ARRAY
V
CC
V
REG
VOLTAGE
REGULATOR
DIGITAL
LOGIC
V
REF
DSP
V
CC
COMPARATOR
COMPARATOR
COMPARATOR
VCC_UV_ERR
V
REG
POR
V
REGA
V
REF
aaa-029736
Figure 3.ꢀVoltage regulation and monitoring
7.1.1 VCC, VREG, VREGA, undervoltage monitor
A circuit is incorporated to monitor the VCC supply voltage and the internally regulated
voltages VREG and VREGA. If any of the voltages fall below the specified undervoltage
thresholds in Table 101, SPI and I2C transactions are terminated. Once the supply
returns above the threshold, the device resumes responses.
7.2 Internal oscillator
The device includes a factory trimmed oscillator as specified in Table 102.
7.3 Pressure sensor signal path
7.3.1 Transducer
See Table 101 and Table 102 for transducer parameters.
FXPS7115D4
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2019. All rights reserved.
Product data sheet
Rev. 3 — 5 December 2019
5 / 72