内容描述: [FXTH87E, Family of Tire Pressure Monitor Sensors]
分类和应用:
文件页数/大小: 183 页 / 1700 K
品牌: NXP [ NXP ]
 浏览型号F87EHHD的Datasheet PDF文件第95页浏览型号F87EHHD的Datasheet PDF文件第96页浏览型号F87EHHD的Datasheet PDF文件第97页浏览型号F87EHHD的Datasheet PDF文件第98页浏览型号F87EHHD的Datasheet PDF文件第100页浏览型号F87EHHD的Datasheet PDF文件第101页浏览型号F87EHHD的Datasheet PDF文件第102页浏览型号F87EHHD的Datasheet PDF文件第103页  
NXP Semiconductors  
FXTH87E  
FXTH87E, Family of Tire Pressure Monitor Sensors  
When the channel is configured for edge-aligned PWM, the channel flag is set when  
the timer counter matches the channel value register that marks the end of the active  
duty cycle period.  
When the channel is configured for center-aligned PWM, the timer count matches the  
channel value register twice during each PWM cycle. In this CPWM case, the channel  
flag is set at the start and at the end of the active duty cycle, which are the times when  
the timer counter matches the channel value register.  
The flag is cleared by the two-step sequence described in Section 11.6.1 "Clearing timer  
interrupt flags".  
12 Other MCU resources  
It is not intended that physical parameter measurements be made during the time that  
LFR may be actively receiving/decoding LF signals; or during the time that the RFM  
may be actively powered up and/or transmitting RF data. The resulting interactions will  
degrade the accuracy of the measurements.  
The FXTH87E measures six physical parameters for use in the tire pressure monitoring  
application: pressure, temperature, battery voltage, two external voltages and an optional  
X- and/or Z-axis acceleration. Each parameter is accessed in a different manner and all  
use firmware subroutine calls as described in Section 16 "Firmware". These subroutines  
initialize some control bits within the sensor measurement interface, SMI, and then place  
the MCU into the STOP4 mode until the measurement is completed with an interrupt  
back to the MCU.  
The accuracy, power consumption and timing specified for any measurement provided  
in the data sheet are only guaranteed if the user obtains a reading using the specified  
firmware subroutine call in Section 16 "Firmware". For additional information, contact  
your NXP sales representative.  
The FXTH87E uses a 6-channel, 10-bit analog-to-digital converter (ADC10) module.  
The ADC10 module is an analog-to-digital converter using a successive approximation  
register (SAR) architecture with sample and hold. Capture of pressure and acceleration  
sensor readings is controlled by the sensor measurement interface (SMI) and capture of  
temperature and voltage readings are controlled by the MCU.  
When making measurements of the various analog voltages the individual blocks will  
first be powered up long enough to stabilize their outputs before a conversion is started.  
The ADC channels are connected in hardware. Conversions are started and ended  
synchronously with the sampling of the voltages.  
The accuracy, power consumption and timing specifications given in the data sheet are  
based on using the assigned firmware subroutines in Section 16 "Firmware" to make  
these measurements and convert them into an 8-bit, 9-bit or 10-bit transfer function.  
These measurement accuracy specifications cannot be guaranteed if the user creates  
custom software routines to convert these measurements. For additional information,  
contact your NXP sales representative.  
Table 96.ꢀADC10 channel assignments  
ADC10  
Channel  
Input Select  
Firmware Call(s)  
Characteristic  
Pressure Sensor  
TPMS_READ_COMP_PRESSURE  
PCODE  
AD0  
Optional X-axis Acceleration TPMS_READ_COMP_ACCEL_X  
Sensor  
AXCODE  
FXTH87ERM  
All information provided in this document is subject to legal disclaimers.  
© NXP B.V. 2019. All rights reserved.  
Reference manual  
Rev. 5.0 — 4 February 2019  
99 / 183  
 
 