NXP Semiconductors  
FXTH87E  
FXTH87E, Family of Tire Pressure Monitor Sensors  
When security is enabled, the RAM is considered a secure memory resource and is  
not accessible through BDM or through code executing from non-secure memory. See  
Section 6.8 "Security" for a detailed description of the security feature.  
None of the RAM locations are used directly by the firmware provided by NXP. The  
firmware routines utilize RAM only through stack operations; and the user needs to be  
aware of stack depth required by each routine as described in the CodeWarrior project  
files supplied by NXP.  
6.7 FLASH  
The FLASH memory is intended primarily for program storage. The operating program  
can be loaded into the FLASH memory after final assembly of the application product  
using the single-wire BACKGROUND DEBUG interface. Because no special voltages  
are needed for FLASH erase and programming operations, in-application programming  
is also possible through other software-controlled communication paths. For a more  
detailed discussion of in-circuit and in-application programming, refer to the HCS08  
Family Reference Manual, Volume I, NXP document number HCS08RMV1/D.  
6.7.1 Features  
Features of the FLASH memory include:  
User Program FLASH Size — 8192 bytes (16 pages of 512 bytes each)  
Single power supply program and erase  
Command interface for fast program and erase operation  
Up to 100,000 program/erase cycles at typical voltage and temperature  
Flexible FLASH protection  
Security feature for FLASH and RAM  
Auto power-down for low-frequency read accesses  
6.7.2 Program and erase times  
Before any program or erase command can be accepted, the FLASH clock divider  
register (FCDIV) must be written to set the internal clock for the FLASH module to a  
frequency (fFCLK) between 150 kHz and 200 kHz. This register can be written only once,  
so normally this write is performed during reset initialization. FCDIV cannot be written if  
the access error flag, FACCERR in FSTAT, is set. The user must ensure that FACCERR  
is not set before writing to the FCDIV register. One period of the resulting clock (1/fFCLK  
)
is used by the command processor to time program and erase pulses. An integer number  
of these timing pulses are used by the command processor to complete a program or  
erase command.  
Table 13 shows program and erase times. The bus clock frequency and FCDIV  
determine the frequency of FCLK (fFCLK). The time for one cycle of FCLK is tFCLK = 1/  
fFCLK. The times are shown as a number of cycles of FCLK and as an absolute time for  
the case where tFCLK = 5 μs. Program and erase times shown include overhead for the  
command state machine and enabling and disabling of program and erase voltages.  
Table 13.ꢀProgram and erase times  
Parameter  
Byte program  
Cycles of FCLK  
Time if FCLK = 200 kHz  
9
4
45 μs  
20 μs [1]  
Byte program (burst)  
FXTH87ERM  