NXP Semiconductors  
FXTH87E  
FXTH87E, Family of Tire Pressure Monitor Sensors  
by the firmware to the application software as either the raw ADC10 result or further  
compensated and scaled for an output between one and the maximum digital value  
minus one. The minimum digital value of zero and the maximum digital value are  
reserved as error codes.  
The signal ranges and their significant data points are shown in Figure 48. In this  
definition the signal source would normally output a signal between SINLO and SINHI  
.
Due to process, temperature and voltage variations this signal may increase its range  
to SINMIN to SINMAX. In all cases the signal will be between the supply rails, so that the  
ADC10 will convert it to a range of digital numbers between 0 and 1023. These digital  
numbers will have corresponding DINMIN, DINLO, DINHI, DINMAX values. The ADC10 digital  
value is taken by the firmware and compensated and scaled to give the required output  
code range.  
UPPER ERROR CASE  
FORCE  
OUTPUT  
TO 511  
OVERFLOW  
VDD  
1023  
511  
510  
CASE  
SINMAX  
SINHI  
DINMAX  
DINHI  
NORMAL CASE  
VDD/2  
512  
256  
SIGNAL  
SOURCE  
FIRMWARE  
ROUTINE  
ADC10  
SENSOR  
ANALOG  
VOLTAGE  
ADC10 RAW  
DIGITAL  
(10-BIT CONVERSION)  
CALCULATED  
DIGITAL  
(9-BIT EXAMPLE)  
SINLO  
DINLO  
SINMIN  
DINMIN  
1
0
VDD  
0
UNDERFLOW  
CASE  
FORCE  
OUTPUT  
TO ZERO  
LOWER ERROR CASE  
aaa-028041  
Figure 48.ꢀMeasurement signal range definitions  
Digital input values below DINMIN and above DINMAX are immediately flagged as being out  
of range and generate error bits and the output is forced to the 0 value.  
Digital values below DINLO (but above DINMIN) or above DINHI (but not DINMAX) will most  
likely cause an output that would be less than 1 or greater than 510, respectively. These  
cases are considered underflow or overflow, respectively. Underflow results will be forced  
to a value of 1. Overflow results will be forced to a value of 510.  
Digital values between DINLO and DINHI will normally produce an output between 1 to  
510 (for a 9-bit result). In some isolated cases due to compensation calculations and  
rounding the result may be less than 1 or greater than 510, in which case the underflow  
and overflow rule mentioned above is used.  
FXTH87ERM  
All information provided in this document is subject to legal disclaimers.  
© NXP B.V. 2019. All rights reserved.  
Reference manual  
Rev. 5.0 — 4 February 2019  
162 / 183  
 