 浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第15页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第16页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第17页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第18页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第20页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第21页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第22页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第23页  
M58LT128HST, M58LT128HSB  
Command interface  
4.3  
Read Electronic Signature command  
The Read Electronic Signature command is used to read the manufacturer and device  
codes, the protection status of the addressed bank, the Protection Register, and the  
Configuration Register.  
One Bus Write cycle is required to issue the Read Electronic Signature command. Once a  
bank is in Read Electronic Signature mode, subsequent Read operations in the same bank  
output the manufacturer code, the device code, the protection status of the addressed bank,  
the Protection Register, or the Configuration Register (see Table 8).  
The Read Electronic Signature command can be issued at any time, even during Program  
or Erase operations, except during Protection Register Program operations. Dual operations  
between the parameter bank and the electronic signature location are not allowed (see  
Table 15: Dual operation limitations for details).  
If a Read Electronic Signature command is issued to a bank that is executing a Program or  
Erase operation the bank go into Read Electronic Signature mode. Subsequent Bus Read  
cycles output the Electronic Signature data and the Program/Erase Controller continues to  
program or erase in the background.  
The Read Electronic Signature command only changes the Read mode of the addressed  
bank. The Read modes of other banks are not affected. Only Asynchronous Read and  
Single Synchronous Read operations should be used to read the Electronic Signature. A  
Read Array command is required to return the bank to Read Array mode.  
4.4  
Read CFI Query command  
The Read CFI Query command is used to read data from the Common Flash Interface  
(CFI).  
One Bus Write cycle is required to issue the Read CFI Query command. Once a bank is in  
Read CFI Query mode, subsequent Bus Read operations in the same bank read from the  
Common Flash Interface. The Read CFI Query command can be issued at any time, even  
during Program or Erase operations.  
If a Read CFI Query command is issued to a bank that is executing a Program or Erase  
operation the bank goes into Read CFI Query mode. Subsequent Bus Read cycles output  
the CFI data and the Program/Erase controller continues to Program or Erase in the  
background.  
The Read CFI Query command only changes the Read mode of the addressed bank. The  
Read modes of other banks are not affected. Only Asynchronous Read and Single  
Synchronous Read operations should be used to read from the CFI. A Read Array  
command is required to return the bank to Read Array mode. Dual operations between the  
Parameter Bank and the CFI memory space are not allowed (see Table 15: Dual operation  
limitations for details).  
See Appendix B: Common Flash Interface, Tables 31, 32, 33, 34, 35, 36, 37, 38, 39 and 40  
for details on the information contained in the Common Flash Interface memory area.  
19/110  