Maximum rating
M29W400DT, M29W400DB
6
Maximum rating
Stressing the device above the rating listed in Table 8: Absolute maximum ratings may
cause permanent damage to the device. Exposure to absolute maximum rating conditions
for extended periods may affect device reliability. These are stress ratings only and
operation of the device at these or any other conditions above those indicated in the
operating sections of this specification is not implied. Refer also to the Numonyx SURE
Program and other relevant quality documents.
Table 8.
Symbol
Absolute maximum ratings
Parameter
Min
Max
Unit
TBIAS
TSTG
TLEAD
VIO
Temperature under bias
Storage temperature
–50
–65
125
°C
°C
°C
V
150
(1)
Lead temperature during soldering
Input or output voltage(2)(3)
Supply voltage
–0.6
–0.6
–0.6
VCC+0.6
4
VCC
V
VID
Identification voltage
13.5
V
1. Compliant with the JEDEC Std J-STD-020B (for small body, Sn-Pb or Pb assermbly), the Numonyx
ECOPACK® 7191395 specification, and the European directive on Restrictions on Hazardous Substances
(RoHS) 2002/95/EU.
2. Minimum voltage may undershoot to –2 V during transition and for less than 20 ns during transitions.
3. Maximum voltage may overshoot to VCC+2 V during transition and for less than 20 ns during transitions.
28/48