欢迎访问ic37.com |
会员登录 免费注册
发布采购

M29W400DT70ZA1 参数 Datasheet PDF下载

M29W400DT70ZA1图片预览
型号: M29W400DT70ZA1
PDF下载: 下载PDF文件 查看货源
内容描述: 4兆位( 512 KB ×8或256 KB ×16 ,引导块) 3 V电源闪存 [4 Mbit (512 Kb x 8 or 256 Kb x 16, boot block) 3 V supply Flash memory]
分类和应用: 闪存
文件页数/大小: 48 页 / 1025 K
品牌: NUMONYX [ NUMONYX B.V ]
 浏览型号M29W400DT70ZA1的Datasheet PDF文件第15页浏览型号M29W400DT70ZA1的Datasheet PDF文件第16页浏览型号M29W400DT70ZA1的Datasheet PDF文件第17页浏览型号M29W400DT70ZA1的Datasheet PDF文件第18页浏览型号M29W400DT70ZA1的Datasheet PDF文件第20页浏览型号M29W400DT70ZA1的Datasheet PDF文件第21页浏览型号M29W400DT70ZA1的Datasheet PDF文件第22页浏览型号M29W400DT70ZA1的Datasheet PDF文件第23页  
M29W400DT, M29W400DB  
Command interface  
4
Command interface  
All Bus Write operations to the memory are interpreted by the command interface.  
Commands consist of one or more sequential Bus Write operations. Failure to observe a  
valid sequence of Bus Write operations will result in the memory returning to Read mode.  
The long command sequences are imposed to maximize data security.  
The address used for the commands changes depending on whether the memory is in 16-  
bit or 8-bit mode. See either Table 5, or Table 6, depending on the configuration that is being  
used, for a summary of the commands.  
4.1  
4.2  
Read/Reset command  
The Read/Reset command returns the memory to its Read mode where it behaves like a  
ROM or EPROM, unless otherwise stated. It also resets the errors in the Status Register.  
Either one or three Bus Write operations can be used to issue the Read/Reset command.  
The Read/Reset command can be issued, between Bus Write cycles before the start of a  
program or erase operation, to return the device to Read mode. Once the program or erase  
operation has started the Read/Reset command is no longer accepted. The Read/Reset  
command will not abort an Erase operation when issued while in Erase Suspend.  
Auto Select command  
The Auto Select command is used to read the manufacturer code, the device code and the  
Block Protection status. Three consecutive Bus Write operations are required to issue the  
Auto Select command. Once the Auto Select command is issued the memory remains in  
Auto Select mode until another command is issued.  
From the Auto Select mode the manufacturer code can be read using a Bus Read operation  
with A0 = V and A1 = V . The other address bits may be set to either V or V . The  
IL  
IL  
IL  
IH  
manufacturer code for Numonyx is 0020h.  
The device code can be read using a Bus Read operation with A0 = V and A1 = V . The  
IH  
IL  
other address bits may be set to either V or V . The device code for the M29W400DT is  
IL  
IH  
00EEh and for the M29W400DB is 00EFh.  
The Block Protection status of each block can be read using a Bus Read operation with  
A0 = V , A1 = V , and A12-A17 specifying the address of the block. The other address bits  
IL  
IH  
may be set to either V or V . If the addressed block is protected then 01h is output on  
IL  
IH  
Data inputs/outputs DQ0-DQ7, otherwise 00h is output.  
4.3  
Program command  
The Program command can be used to program a value to one address in the memory array  
at a time. The command requires four Bus Write operations, the final write operation latches  
the address and data and starts the Program/Erase controller.  
If the address falls in a protected block then the Program command is ignored, the data  
remains unchanged. The Status Register is never read and no error condition is given.  
19/48  
 复制成功!