 浏览型号M29W400DT70ZA1的Datasheet PDF文件第17页浏览型号M29W400DT70ZA1的Datasheet PDF文件第18页浏览型号M29W400DT70ZA1的Datasheet PDF文件第19页浏览型号M29W400DT70ZA1的Datasheet PDF文件第20页浏览型号M29W400DT70ZA1的Datasheet PDF文件第22页浏览型号M29W400DT70ZA1的Datasheet PDF文件第23页浏览型号M29W400DT70ZA1的Datasheet PDF文件第24页浏览型号M29W400DT70ZA1的Datasheet PDF文件第25页  
M29W400DT, M29W400DB  
Command interface  
within about 100 µs, leaving the data unchanged. No error condition is given when protected  
blocks are ignored.  
During the erase operation the memory will ignore all commands. It is not possible to issue  
any command to abort the operation. Typical chip erase times are given in Table 4. All Bus  
Read operations during the Chip Erase operation will output the Status Register on the Data  
inputs/outputs. See the section on the Status Register for more details.  
After the Chip Erase operation has completed the memory will return to the Read mode,  
unless an error has occurred. When an error occurs the memory will continue to output the  
Status Register. A Read/Reset command must be issued to reset the error condition and  
return to Read mode.  
The Chip Erase command sets all of the bits in unprotected blocks of the memory to ’1’. All  
previous data is lost.  
4.8  
Block Erase command  
The Block Erase command can be used to erase a list of one or more blocks. Six Bus Write  
operations are required to select the first block in the list. Each additional block in the list can  
be selected by repeating the sixth Bus Write operation using the address of the additional  
block. The Block Erase operation starts the Program/Erase controller about 50 µs after the  
last Bus Write operation. Once the Program/Erase controller starts it is not possible to select  
any more blocks. Each additional block must therefore be selected within 50 µs of the last  
block. The 50 µs timer restarts when an additional block is selected. The Status Register  
can be read after the sixth Bus Write operation. See the Status Register for details on how  
to identify if the Program/Erase controller has started the Block Erase operation.  
If any selected blocks are protected then these are ignored and all the other selected blocks  
are erased. If all of the selected blocks are protected the Block Erase operation appears to  
start but will terminate within about 100 µs, leaving the data unchanged. No error condition  
is given when protected blocks are ignored.  
During the Block Erase operation the memory will ignore all commands except the Erase  
Suspend command. Typical block erase times are given in Table 4. All Bus Read operations  
during the Block Erase operation will output the Status Register on the Data inputs/outputs.  
See the section on the Status Register for more details.  
After the Block Erase operation has completed the memory will return to the Read mode,  
unless an error has occurred. When an error occurs the memory will continue to output the  
Status Register. A Read/Reset command must be issued to reset the error condition and  
return to Read mode.  
The Block Erase command sets all of the bits in the unprotected selected blocks to ’1’. All  
previous data in the selected blocks is lost.  
4.9  
Erase Suspend command  
The Erase Suspend command may be used to temporarily suspend a Block Erase operation  
and return the memory to Read mode. The command requires one Bus Write operation.  
The Program/Erase controller will suspend within the Erase Suspend Latency time after the  
Erase Suspend command is issued (see Table 4 for numerical values). Once the  
Program/Erase controller has stopped the memory will be set to Read mode and the Erase  