DC and AC parameters
Table 17. AC characteristics(1)
M25PX64
Test conditions specified in Table 13 and Table 14
Symbol
Alt.
Parameter
Min
Typ(2)
Max Unit
Clock frequency for the following
instructions: DOFR, DIFP, FAST_READ,
fC
fC SSE, SE, BE, DP, WREN, WRDI, RDID, D.C.
RDSR, WRSR, ROTP, PP, POTP,
WRLR, RDLR, RDP
75
33
MHz
fR
Clock frequency for read instructions
tCLH Clock High time
tCLL Clock Low time
Clock rise time(5) (peak to peak)
D.C.
6
MHz
ns
(3)
tCH
(2)
tCL
6
ns
(4)
tCLCH
0.1
0.1
5
V/ns
V/ns
ns
(4)
tCHCL
Clock fall time(5) (peak to peak)
tCSS S active setup time (relative to C)
S not active hold time (relative to C)
tDSU Data in setup time
tSLCH
tCHSL
tDVCH
tCHDX
tCHSH
tSHCH
tSHSL
5
ns
2
ns
tDH Data in hold time
5
ns
S active hold time (relative to C)
S not active setup time (relative to C)
tCSH S deselect time
5
ns
5
ns
80
ns
(4)
tSHQZ
tDIS Output disable time
8
8
6
ns
Clock Low to Output valid under 30 pF
ns
tCLQV
tV
Clock Low to Output valid under 10 pF
ns
tCLQX
tHLCH
tCHHH
tHHCH
tCHHL
tHO Output hold time
0
5
5
5
5
ns
HOLD setup time (relative to C)
HOLD hold time (relative to C)
HOLD setup time (relative to C)
HOLD hold time (relative to C)
tLZ HOLD to Output Low-Z
tHZ HOLD to Output High-Z
Write protect setup time
ns
ns
ns
ns
(4)
tHHQX
8
8
ns
(4)
tHLQZ
ns
(6)
tWHSL
20
ns
(6)
tSHWL
Write protect hold time
100
ns
Enhanced program supply voltage High
(VPPH) to Chip Select Low
(7)
tVPPHSL
200
ns
(4)
tDP
S High to deep power-down mode
S High to standby mode
3
μs
μs
(4)
tRDP
30
58/68