Numonyx™ StrataFlash Embedded Memory (J3-65nm)
Programming Confirm command is written to the device, a command sequence error
occurs and SR[7,5,4] are set. If an error occurs while writing to the array, the device
stops programming, and SR[7,4] are set, indicating a programming failure.
When Buffered Programming has completed, additional buffer writes can be initiated by
issuing another Buffered Programming Setup command and repeating the buffered
program sequence.
If an attempt is made to program past an erase-block boundary using the Buffered
Program command, the device aborts the operation. This generates a command
sequence error, and SR[5,4] are set.
If Buffered programming is attempted while VPEN is below VPENLK, SR[4,3] are set. If
any errors are detected that have set Status Register bits, the Status Register should
be cleared using the Clear Status Register command.
Note:
In x8 mode, a maximum of 256 bytes of data can be loaded into the write buffer as N
can have a max value of FFh.
8.3
Suspend/Resume
An erase or programming operation can be suspended to perform other operations, and
then subsequently resumed. Please refer to Chapter 9.0, “Suspend/Resume” for
details.
December 2008
319942-02
Datasheet
25