Electrical Characteristics
Symbol
ICCTZ
Parameter
Transmitter Supply Current
Power Down
RECEIVER SUPPLY CURRENT
ICCRW
Receiver Supply Current, Worst
Case
(Continued)
Over recommended operating supply and temperature ranges unless otherwise specified.
Conditions
PWR DWN = Low
Driver Outputs in
TRI-STATE
®
under
Power Down Mode
C
L
= 8 pF, Worst
Case Pattern
(Figures
1, 4 ),
T
A
= −40˚C to
+85˚C
C
L
= 8 pF, 16
Grayscale Pattern
(Figures 2, 4 ),
T
A
=
−40˚C to +85˚C
PWR DWN = Low
Receiver Outputs Stay Low during
Power Down Mode
Note 1:
“Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed. They are not meant to imply that the device
should be operated at these limits. The tables of “Electrical Characteristics” specify conditions for device operation.
Note 2:
Typical values are given for V
CC
= 3.3V and T
A
= +25C.
Note 3:
Current into device pins is defined as positive. Current out of device pins is defined as negative. Voltages are referenced to ground unless otherwise speci-
fied (except V
OD
and
∆V
OD
).
Note 4:
V
OS
previously referred as V
CM
.
Min
Typ
10
Max
55
Units
µA
TRANSMITTER SUPPLY CURRENT
f = 32.5 MHz
f = 37.5 MHz
f = 65 MHz
f = 32.5 MHz
f = 37.5 MHz
f = 65 MHz
49
53
78
28
30
43
10
65
70
105
45
47
60
55
mA
mA
mA
mA
mA
mA
µA
ICCRG
Receiver Supply Current, 16
Grayscale
ICCRZ
Receiver Supply Current
Power Down
www.national.com
4