Table 10. Measurement points
Supply voltage
VCC
Input
Output
VM
VM
VI
1.65 V to 1.95 V
2.3 V to 2.7 V
2.7 V
0.5VCC
0.5VCC
1.5 V
1.5 V
0.5VCC
VCC
VCC
2.7 V
2.7 V
VCC
0.5VCC
0.5VCC
1.5 V
3.0 V to 3.6 V
4.5 V to 5.5 V
1.5 V
0.5VCC
9
(;7
9
&&
5
/
9
9
2
,
*
'87
5
7
&
/
5
/
PQDꢈꢁꢈ
Measurement points are given in Table 11.
Definitions test circuit:
RL = Load resistance.
CL = Load capacitance including jig and probe capacitance.
RT = Termination resistance should be equal to output impedance Zo of the pulse generator.
VEXT = External voltage for measuring switching times.
Fig 11. Test circuit for measuring switching times
Table 11. Measurement points
Supply voltage
VCC
Input
VI
Load
CL
VEXT
tr = tf
RL
tPLH, tPHL
open
1.65 V to 1.95 V
2.3 V to 2.7 V
2.7 V
VCC
VCC
2.7 V
2.7 V
VCC
2.0 ns
2.0 ns
2.5 ns
2.5 ns
2.5 ns
30 pF
30 pF
50 pF
50 pF
50 pF
1 k
500
500
500
500
open
open
3.0 V to 3.6 V
4.5 V to 5.5 V
open
open
74LVC1G57_Q100